Venting Kits - Kenmore W10562368A Installation Instructions Manual

27" wide electric models
Table of Contents

Advertisement

Available languages

Available languages

Venting Kits

For more information, call 1-800-901-2042, or visit us at
www.applianceaccessories.com. In Canada, call
1-800-807-6777 or visit us at www.whirlpoolparts.ca.
Part
Description
Number
8171587RP
0–5" Metal vent periscope
4396037RP
0"–18" Metal vent periscope
4396011RP
18"–29" Metal vent periscope
4396014
29"–50" Metal vent periscope
4392892
In-Wall metal DuraVent™ Periscope
279818
4-way vent kit – white
W10470674
4-way vent kit – universal grey
4396028
Sure Connect™ venting kit
(over-the-top installation)
4396009RP
5' Universal connect vent, flexible dryer venting
4396010RP
6' SecureConnect™ vent, flexible dryer venting
4396013RB
Dryer vent installer's kit
4396033RP
5' Flexible dryer venting with clamps
4396727RP
8' Flexible dryer venting with clamps
4396004
Dryer offset elbow
4396005
Wall offset elbow
4396006RW
DuraSafe™ close elbow
4396007RW
Through-the-wall vent cap
4396008RP
4" Steel dryer venting clamps – 2 pack
8212662
Flush mounting louvered vent hood 4"
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path:
Select route that will provide straightest and most direct
path outdoors.
Plan installation to use fewest number of elbows and turns.
When using elbows or making turns, allow as much room
as possible.
Bend vent gradually to avoid kinking.
Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
Use following "Vent System Chart" to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in "Vent System Chart." Exhaust systems longer than those
specified will:
Shorten life of dryer.
Reduce performance, resulting in longer drying times
and increased energy usage.
The "Vent System Chart" provides venting requirements that will
help achieve best drying performance.
Vent System Chart
Number of
Type
90° turns
of vent
or elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
NOTE: Side and bottom exhaust installations have a 90º turn
inside the dryer. To determine maximum exhaust length, add
one 90º turn to the chart.
Box/louvered
Angled
hoods
hoods
58 ft. (17.7 m)
64 ft. (20 m)
54 ft. (16.5 m)
48 ft. (14.6 m)
44 ft. (13.4 m)
38 ft. (11.6 m)
35 ft. (10.7 m)
29 ft. (8.8 m)
27 ft. (8.2 m)
21 ft. (6.4 m)
15