Locatlon Requlrements - Kenmore 110.77102310 Installation Instructions Manual

27" wide electric models
Table of Contents

Advertisement

Available languages

Available languages

Parts supplied:
Leveling legs (4)
Parts package
is located
in dryer drum.
Check that all parts
are included.
Parts needed:
Check (oca( codes.
Check existing
electrical
supply
and venting,
and read "Electrical
Requirements"
and "Venting
Requirements"
before
purchasing
parts.
Mobile
home installations
require
metal
exhaust
system
hardware,
available
for purchase
from the dealer
from
whom you purchased
your dryer.
For further
information,
please
reference
the "Assistance
or Service"
section
of the
Use and Care Guide.
If using
a power
supply
cord:
Use a UL listed power
supply
cord
kit marked
for use with clothes
dryers.
The kit should contain:
[]
A UL listed 30=amp
power
supply
cord,
rated
120/240
volt
minimum.
The cord should
be type SRD or SRDT and be
at least 4 ft. (1.22 m) long. The wires that connect
to the
dryer
must end in ring terminals
or spade
terminals
with
upturned
ends.
[]
A UL listed strain relief.
Location Requirements
Explosion Hazard
Keep flammable
materials
and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion,
or fire.
You wii(
need:
[]
A location
allowing
for proper
exhaust
installation.
See _'Venting
Requirements."
[]
A separate
30 amp circuit.
[]
If you are using power supply
cord,
a grounded
electrical
out(et located
within
2 ft. (610 ram) of either
side of dryer.
See
"Eiectrica(
Requirements."
[]
A sturdy floor
to support
the total
weight
(dryer
and load)
of 200 (bs. (90.7
kg). The combined
weight
of a companion
appliance
should
also be considered.
[]
Level floor
with
maximum
slope of 1" (25 rnm) under entire
dryer. (If slope is greater
than 1" [25 ram], install Extended
Dryer
Feet Kit, Part Number
279810.)
If not level, clothes
may not tumble
properly
and automatic
sensor cycles
may
not operate
correctly.
Do not operate
your dryer
at temperatures
below
45°F (7°C).
At
lower temperatures,
the dryer
might not shut off at the end of an
automatic
cycle.
Drying
times can be extended.
The dryer
must not be installed
or stored
in an area where it will
be exposed
to water
and/or
weather.
Check code requirements.
Some codes limit, or do not permit,
installation
of the dryer
in garages,
closets, mobile
homes, or
sleeping
quarters.
Contact
your
local
building
inspector.
installation clearances:
The location
must be large
enough
to allow
the dryer door
to open
fully.
Dryer
Dimensions
_------ 27" ----_
(686ram) I
i
43"
(1092 ram)
...................................
d_
...... _
U
T
11/2'
(38 ram)
291/2"
(749 ram)
1 33/4 ''
(349 ram)
• =_ 29V2" -_
(749 ram)
A. Wide
opening
side-swing
door
B. Wide
opening
hamper
door
*Most
installations
require
a minimum
51/2'' (140 mm) clearance
behind
the dryer
for the exhaust
vent with elbow.
See "Venting
Requirements."
Minimum spacing for recessed area or closet
installation
The dimensions
shown following
are for the minimum
spacing
allowed:
[]
Additional
spacing
should
be considered
for ease of installation
and servicing.
[]
Additiona(
clearances
might be required
for wall, door, and
floor
moldings.
[]
Additional
spacing
of 1" (25 rnm) on a(( sides of the dryer is
recommended
to reduce
noise transfer.
[]
For closet
insta((ation, w(th a door, minimum
ventilation
openings
in the top and bottom
of the door are required.
Louvered
doors with
equivalent
ventilation
openings
are acceptable.
[]
Companion
appliance
spacing
should also be considered.
4