SW No
Setting items
Setting No.
Contents
Fact. set
Explanation
70
FSK check before
00
OFF
When this unit can not receive the high speed
phase-C
01
ON
01
training signal by the echo of CFR (E-52), set
to OFF (SETTING
No.
00).
71
Allowance of Error lines
00
32
When receiving consecutive
error lines
01
64
01
exceeding the setting number, the unit moves
02
96
to the sequence of bad copy quality and send
03
128
RTN to transmitter.
04
160
When the E-30 occurs frequently,
set the
05
192
number to higher value but printing quality is
06
224
getting worse.
07
256
08
No limit
74
Carrier OFF detection
00
0 sec.
This is to set the allowance of the carrier off
duration
01
0.5 sec.
duration.
02
1.0 sec.
If the carrier off duration is less than the
03
1.5 sec.
setting value, reception is continued.
04
2.0 sec.
05
2.5 sec.
06
3.0 sec.
06
I
I
bO.5 sec. step.
12
6.0 sec.
75
Transmission
start
00
2400 BPS
This is to set the training start speed of the
speed
01
4800 BPS
MODEM.
02
7200 BPS
It is recommended
that if Tx. error occurs
03
9600 BPS
03
frequently set to 4800BPS.
76
TSI
00
None
This is to set the condition of transmitting
TSI.
01
Transmit in
anycase
02
Transmit only
02
when CSI
receives
77
DCS timing
00
Response to the
00
This is to set the response of DCS
first DIS
corresponding
to DIS.
01
Response to the
In order to consider the influence of the echo
second DIS
while transmitting
to overseas fax.
2nd DIS (SETTING No. 01 )might be effective.
78
Interval between DCS
00
75 ms
00
This is to set the interval between DCS and
and Training
01
0.3 sec.
training for the purpose of correcting the
02
0.5 sec.
mismatching
of between SANYO and other
manufacturer's
machine.
ITU-T recommendation
is 75 + 20 ms.
79
Interval between RTC
00
75 ms
00
This is to set the interval between RTC and Q
and Q
01
0.3 sec.
for the purpose of correcting the mismatching
02
0.5 sec.
of between SANYO and other manufacturer's
machine.
ITU-T recommendation
is 75 & 20 ms.
80
Document jam
00
1.5m
00
This selection defines the original length the
01
3.0 m
SFX-21 O can accept.
02
No limit
81
FSK release delay
00
0 ms
00
This is to set the delay for correcting the
01
100 ms
mismatching
of between SANYO and other
02
200 ms
manufacturer's
machine.
03
300 ms
04
400 ms
82
Transmission attenuator
00
0 dB
This is to set the Tx.level attenuation
for
I
I
09
control and video signals.
15
–15 dB
.-