Sanyo SFX-110 Service Manual page 37

Hide thumbs Also See for SFX-110:
Table of Contents

Advertisement

.
-=
—.
SW No
Setting items
Setting No.
Contents
Fact. set
Explanation
36
Halftone pattern
00
Pattern 1
Determines the Dither pattern used for a
01
Pattern 2
01
Halftone transmission
and copy.
54
Auto Progress
00
OFF
+Need
to pressing START for manual
transmission
Tx.
01
ON
01
No
need to pressing START for manual Tx.
RAM CODE (FOR SERVICE-MAN)
SW No
Setting items
Setting No.
Contents
Fact. set
Explanation
02
Hook-up ALARM
00
OFF
00
When built-in or extension handset is
01
ON
remained in OFF Hook after operation,
alarm
is generated.
31
Transmission
report
00
OFF
00
No Tx. report is issued.
01
ON(after each
*Tx.
report is issued after each Tx.
transmission)
02
ON(when error
Tx. report is issued only when Tx. error
condition occur)
occurs.
37
Character edge
00
Enhancement
00
To
enhance character edge, set higher
enhancement
level for
01
level can be set
number.
halftone
02
by 4-steps
03
49
Delete short ICM
00
OFF
When no caller's voice is recorded, it is
01
ON
01
automatically
deleted when setting "ON".
60
Communication
mode
00
AUTO
00
This RAM SW. fixes the communication
mode
01
G3
and is normally set on AUTO.
61
Manual hook up
00
OFF
00
[START] is effective without lifting the handsei
01
ON
when the setting is ON (SETTING No. 01).
Used for hooking up 2 facsimiles with back to
back connection.
62
Communication
speed
00
OFF
00
Set
communication
speed display ON or OFF
display
01
ON
63
Line monitor
00
OFF
00
Set line monitor ON or OFF.
01
ON
66
CED check time
00
35
sec.
00
Set the waiting time for the CED signal after
01
38.5 sec.
dialing.
02
42
sec.
03
45.5 sec.
04
49
sec.
I
I
* 3.5 sec. step
16
91
sec.
67
Receiving start speed
00
4800 BPS
At 4800BPS, this unit has more tolerance
01
9600 BPS
01
against the line noise but the receiving start
speed is a half of 9600BPS. When the
receiving error occurs frequently, set to
4800BPS.
68
CED frequency
00
2100Hz
00
When transmitting
overseas, this work to
01
IIOOHZ
guard against interchange
echoes, if set to
1100Hz (SETTING
No.
01).
69
TCF check interval
V29
V27
00
5ms
l15ms
00
Set the time from the recognition of the
01
60ms
170ms
training by the Modem to starting the training
02
100ms
210ms
check(TCF). Set to correct the mismatching
of between SANYO and other Mfr's machine.
36

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sfx-210

Table of Contents