Specifications; Electrical Specifications; Physical Specifications - Motorola AP-8132 Installation Manual

Hide thumbs Also See for AP-8132:
Table of Contents

Advertisement

38
4

Specifications

4.1 Electrical Characteristics
An AP-8132 model access point has the following electrical characteristics:
Operating Current &
Voltage
4.2 Physical Characteristics
An AP-8132 model access point has the following physical characteristics:
Dimensions
Housing
Weight (without
facade)
Operating
Temperature
Storage Temperature -40°F to 185°F/-40°C to 85°C
Operating Humidity
Storage Humidity
Operating Altitude
(max)
Storage Altitude
(max)
Electrostatic
Discharge
48VDC, 0.625A (AUX input voltage)
48VDC, 0.75A (PWRS-14000-247R power supply)
802.3at, 25.5W (AP-PSBIAS-2P3-ATR Power Injector)
9 inches x 6.00 inches x 1.75 inches
22.9 cm x 15.2 cm x 4.4 cm
Metal
3.2 lbs / 1.45 kg
32°F to 122°F/0°C to 50°C
5 to 95% Relative Humidity non-condensing
85% Relative Humidity non-condensing
8,000 ft @ 28C
30,000 ft @ 12C
+/-15kV Air and +/-8kV Contact @ 50% Relative Humidity