Single-stage fan assisted combustion system downflow/horizontal condensing, gas-fired furnace

Advertisement

Downflow/Horizontal
Condensing,
Gas-Fired Furnace
XB 90
TDC1B040A9241A, TDC1B060A9361A
TDC1B080A9421A, TDC1C100A9481A
TDC1D120A9601A
Single-Stage Fan Assisted
Combustion System
PUB. NO. 22-1670-10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TDC1B040A9241A and is the answer not in the manual?

Questions and answers

Summary of Contents for Trane TDC1B040A9241A

  • Page 1 Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TDC1B040A9241A, TDC1B060A9361A TDC1B080A9421A, TDC1C100A9481A TDC1D120A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1670-10...
  • Page 2: Feature Summary

    Low energy power venter limit sensors, blowers, gas valve, flame b. Vent proving pressure switch. control and includes self diagnostics for ease of service. Also contains connec- tion points for E.A.C./humidifier. © Trane 2015 Pub. No. 22-1670-10...
  • Page 3: Table Of Contents

    Contents Feature Summary Features and Benefits Standard Equipment Optional Equipment General Data TDC1B040A9241A TDC1B060A9361A TDC1B080A9421A TDC1C100A9481A TDC1D120A9601A Performance Data Electrical Data Field Wiring Dimensions Pub. No. 22-1670-10...
  • Page 4: Features And Benefits

    Features and Benefits XB 90 STANDARD EQUIPMENT • Downflow power supply 115/1/60 • Selectable cooling fan off delay elimi- nates need for BAY24X045 time delay • Downflow convertible to horizontal on relay left side • Integrated solid state control with •...
  • Page 5: Optional Equipment

    Features and Benefits XB 90 OPTIONAL EQUIPMENT Thermostat, Electronic, Non-programmable 1 Heating/1 Cool ..............TCONT200AN11AA [ ] Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ............ TCONT800AS11AA [ ] Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................BAYSTAT305 [ ] Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ............... BAYSTAT300 [ ] Propane Conversion Kit ............................
  • Page 6: General Data

    General Data PRODUCT SPECIFICATIONS 1 MODEL TDC1B040A9241A TDC1B060A9361A TDC1B080A9421A TYPE Downflow / Horizontal Downflow / Horizontal Downflow / Horizontal RATINGS 2 Input BTUH 40,000 60,000 80,000 Capacity BTUH (ICS) 3 38,000 56,000 74,000 AFUE 92.1 92.1 92.1 Temp. rise (Min.-Max.) °F.
  • Page 7 General Data PRODUCT SPECIFICATIONS 1 MODEL *DC1C100A9481A *DC1D120A9601A TYPE Downflow / Horizontal Downflow / Horizontal RATINGS 2 Input BTUH 100,000 120,000 Capacity BTUH (ICS) 3 93,000 112,000 AFUE 92.1 92.1 Temp. rise (Min.-Max.) °F. 35 - 65 40 - 70 BLOWER DRIVE DIRECT DIRECT...
  • Page 8: Tdc1D120A9601A

    1225 1159 CFM VS. TEMPERATURE RISE Cubic Feet Per Minute (CFM) MODEL 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 TDC1B040A9241A 56 TDC1B060A9361A TDC1B080A9421A TDC1C100A9481A TDC1D120A9601A Pub. No. 22-1670-10...
  • Page 9: Electrical Data

    Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES From Dwg. D342798 Pub. No. 22-1670-10...
  • Page 10 Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES From Dwg. D342798 Pub. No. 22-1670-10...
  • Page 11: Field Wiring

    Field Wiring FIELD WIRING DIAGRAM FOR HEATING ONLY TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg.. 21B340387 Rev. 1 FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) TO 115 V 1 PH., 60 HZ., POWER...
  • Page 12 Field Wiring From Dwg.. 21B341422 Rev. 1 From Dwg.. 21B341423 Rev. 1 Pub. No. 22-1670-10...
  • Page 13: Dimensions

    Dimensions TDC1 OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES) Pub. No. 22-1670-10...
  • Page 14 04/15 Trane 6200 Troup Highway Tyler, TX 75707 Since Trane has a policy of continuous product and product data improvement, it reserves the right to www.trane.com change design and specifications without notice.

Table of Contents