Xl 90 downflow/horizontal two-stage condensing gas-fired furnace

Advertisement

Downflow/Horizontal
Two-stage Condensing
Gas-Fired Furnace
XL 90
TDX060,080,100,120R-V
Direct Vent with Variable Speed Inducer
PUB. NO. 22-1706-01-0400 (EN)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TDX060R936V and is the answer not in the manual?

Questions and answers

Summary of Contents for Trane TDX060R936V

  • Page 1 Downflow/Horizontal Two-stage Condensing Gas-Fired Furnace XL 90 TDX060,080,100,120R-V Direct Vent with Variable Speed Inducer PUB. NO. 22-1706-01-0400 (EN)
  • Page 2: Feature Summary

    General Features Natural Gas Models Condensate Drain Built-in trap which can drain from either Central heating furnace designs are certified by the American Gas Association side when the furnace is installed upflow. for both natural and L.P. gas. Limit setting Air Delivery and rating data were established and The variable speed, direct drive blower...
  • Page 3: Table Of Contents

    Contents Feature Summary Features and Benefits Standard Equipment Optional Equipment General Data TDX060R936V TDX080R942V TDX100R948V TDX120R960V Performance Data Electrical Data Field Wiring Dimensions 22-1706-01-0400 (EN)
  • Page 4: Features And Benefits

    Features and Benefits XL 90 STANDARD EQUIPMENT • Direct or nondirect vent application • Adjustable fan off times • Convertible to horizontal on left side • Single pipe venting • Power supply 115/1/60 • Cleanable high velocity filters • 2-stage gas valve •...
  • Page 5: Optional Equipment

    Features and Benefits XL 90 OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling ..................BAYSTAT241 [ ] Thermostat, Mechanical Heating Only With Fan Switch ................... BAYSTAT303 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ................AY28X092 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................BAYSTAT305 [ ] Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling ............
  • Page 6: General Data

    General Data TDX-R-V PRODUCT SPECIFICATIONS TDX060R936V TDX080R942V TDX100R948V TDX120R960V MODEL RATINGS2 39000 52000 65000 78000 1st Stage Input BTUH 36000 48000 60000 72000 1st Stage Capacity BTUH (ICS)3 60000 80000 100000 120000 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS)3...
  • Page 7: Performance Data

    HIGH - Black 1487 1425 1362 1286 1209 1125 1040 MED.-HIGH - Blue 1342 1291 1240 1182 1124 1047 TDX060R936V MED.-LOW - Yellow 1181 1147 1113 1061 1009 LOW - Red HIGH - Black 1547 1498 1445 1386 1323 1254...
  • Page 8 VENT LENGTH TABLE MAXIMUM TOTAL EQUIVALENT LENGTH IN FEET ALTITUDE FOR VENT AND INLET AIR (SEE NOTES) 0-7,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH PIPE TDX060R936V TDX080R942V TDX100R948V Not Allowed TDX120R960V Not Allowed Not Allowed 7,000-9,500 Feet 2 INCH PIPE 2.5 INCH PIPE...
  • Page 9: Electrical Data

    Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES TDX060,080,100,120R-V LEGEND From Dwg. 21D341250 P02 22-1706-01-0400 (EN)
  • Page 10: Field Wiring

    Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING From Dwg. 21B341333 Rev. 0 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT From Dwg. 21B341332 Rev. 0 22-1706-01-0400 (EN)
  • Page 11 Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341335 Rev. 0 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341334 Rev. 0 22-1706-01-0400 (EN)
  • Page 12: Twinning Field Wiring

    Twinning Field Wiring Twinning Connection Diagram For Twinning UX/DX-R Furnaces - 2 Stage Heat / 2 Stage Cooling Thermostat From Dwg. 21B341338 Rev. 0 Twinning Connection Diagram For Twinning UX/DX-R Furnaces - 2 Stage Heat / 1 Stage Cooling Thermostat From Dwg.
  • Page 13 Twinning Field Wiring Twinning Connection Diagram For Twinning UX/DX-R Furnaces - 1 Stage Heat / 1 Stage Cooling Thermostat From Dwg. 21B341336 Rev. 0 22-1706-01-0400 (EN)
  • Page 14: Dimensions

    Dimensions TDX-R-V OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES) MODEL Notes: TDX060R936V 1. TDX100R960V requires 2-1/2" or 3" and TDX120R960V 17-1/2" 2-1/4" 16-1/4" 16" 7-1/2" 2" TDX080R942V requires a 3" diameter vent pipe. 2. Clearance required at top of plenum is 1"...
  • Page 15 Notes 22-1706-01-0400 (EN)
  • Page 16 The Trane Company Unitary Products Group 6200 Troup Highway Tyler, TX 75707-9010 www.trane.com Since The Trane Company has a policy of continuous product and product data improvement, it reserves the An American Standard Company right to change design and specifications without notice.