Nozzle (3) and Needle (12) – Remove
parts in the following order: 14, 13, 12,
1, 2 and 3. Examine the seal (4) and
replace if damaged. Replace any other
worn or damaged parts and re-assemble
in
reverse
order.
tightening torque for nozzle (3) 20-27
Nm (15-20 lbf ft)
Packing – Remove parts
Unscrew cartridge (26). Fit new cartridge
finger tight. Re-assemble parts 12, 13,
and 14 and tighten Packing Nut (25) with
Spanner – order SPN-5
Cleaning Brush – order 4900-5-1-K3
Pressure gauge Attachment – order GA-515
Gun Mounted Regulator – order DVR-501
Lubricant - order GL-1-K10

Replacement of Parts

Recommended
14, 13, 12.
Accessories
®
Scrubs
heavy duty towels, capable
of removing paint, grease,
grime and dirt from hands
and tools whout the use of
water. Available in buckets
of 72 wipes.
Order 192218
7
spanner sufficient to seal but to allow
free movement of needle. Lubricate with
gun oil.
Air valve – Remove parts 17, 16 and
15.
Clean
or
assemble parts in reverse order.
Spreader valve – Caution: always
ensure that the valve is in the fully open
position by turning screw fully counter-
clockwise before fitting to body.
are pre-moistened
© 2003 ITW Finishing Systems and Products
replace
Valve.
E
E
Re-

Hide quick links: