ERROR CODE
01Er
PAN Error
03Er
TILT Error
05Er
Color Wheel Error
06Er
Fix Gobo Wheel Error
ELATION© RAYZOR BEAM 2R™
E R R O R
C O D E S
The PAN movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a motor
failure (defective motor or a defective motor IC drive on the main PCB).
This error may also be displayed if the head/yoke was blocked during a
reset function.
The TILT movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a motor
failure (defective motor or defective motor IC drive on main PCB). This error
may also be displayed if the head was blocked during a reset function.
The Color Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a stepper motor failure (defective motor or defective motor IC
drive on main PCB).
The Gobo Wheel 1 movement is not located in the default position after
the reset. This message will appear after a fixture reset if the
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a stepper motor failure (defective motor or defective motor IC
drive on main PCB).