Coarse Filter

To remove the coarse fi lter:
1. Remove the sump fi lter. (See
2. Turn the spray arm hub counterclockwise and
remove it from the tub.
3. Lift the coarse fi lter from the dishwasher.
Coarse Filter
Note: Insure the spray arm bearing is in the proper
location before assembly.
The fl ood switch contacts will open if water reaches
the fl oat stem inside the dishwasher. The switch will
Sump Filter.)
only terminate the voltage to the water valve.
To remove the fl ood switch:
1. Remove two 1/4-in. hex-head screws and the
2. Disconnect the fl ood switch wiring harness.
3. Remove the 2 Phillips-head screws holding the
4. Pull the fl ood switch out of the bracket.
Bearing
– 29 –
Flood Switch
access panel.
switch to the dishwasher.
Disconnect

Hide quick links: