Console - GEAppliances PermaTuf GLD28**V Technical Service Manual

Table of Contents

Advertisement

Console

To remove the console (PermaTuf tub models):
1. Remove the control board. (See
2. Remove the pocket handle or towel bar handle.
(See
or
Pocket Handle
3. Remove the outer vent. (See
4. Disconnect the 4 wires from the door switch
assembly.
Disconnect
5. Pull the console out from the outer door panel.
To remove the console (stainless steel tub models):
1. Remove the control board. (See
2. Disconnect the 2 wires from the door switch.
(See
Door Switch Assembly
3. Remove the pocket handle or towel bar handle.
(See
or
Pocket Handle
4. Pull the console out from the outer door panel.
.)
Control Board
Towel Bar Handle.)
Vent.)
Disconnect
Console
.)
Control Board
, step 3.)
Towel Bar Handle.)
Lens
The console must be removed to access the lens,
which adheres to the front panel with double-
backed tape. A new lens will come with the console
as a kit.
To remove the lens:
1. Remove the console. (See
2. Pry the lens off the door panel with a fl at blade
screwdriver.
Lens
Outer Door Panel (PermaTuf Tub Models)
To remove the outer door panel:
1. Remove the inner door panel. (See
Panel (PermaTuf Tub Models).)
2. Disconnect the control board wiring harnesses.
(See
Control Board
3. Disconnect the 4 wires from the door switch
assembly. (See
Console
4. Remove the 2 Phillips-head screws from the
bottom of the door (1 on each side).
– 23 –
Console.)
Adhesive
Inner Door
.)
, step 4.)
(Continued next page)