To remove the mid spray arm (stainless steel tub
models):
1. Disengage the left upper rack slide by pressing
the lever down while pulling the rack out.
2. Disengage the right upper rack slide by pressing
the lever up while pulling the rack out.
3. Remove the 1/4-in. hex-head screw from the
spray arm.
Upper Spray Arm
Remove the upper spray arm by removing the 1/4-
in. hex-head screw holding the arm to the conduit.

Fine Filter

To remove the fi ne fi lter:
1. Remove the lower spray arm. (See
Arm.)
2. Rotate the hub nut counterclockwise. Lift the
hub nut off the fi ne fi lter.
3. Lift the fi ne fi lter off the spray arm hub.
Spray Arm Hub
– 27 –
Lower Spray
Hub Nut
Fine Filter