10 | Installation
4.2
Requirements of the installation location
•
Comply with the specific instructions for each State.
•
Install the appliance in an outdoor location where it will not
be exposed to temperatures below zero.
•
Install the appliance in accordance with the minimum
installation clearances indicated in Fig. 5, according to
AS5601.
D
Fig. 5
Minimum clearances (use as a guide only, always refer to AS/NZS5601)
[D] Openable Door
[T] Flue terminal
[M] Gas meter
[I]
Mechanical air inlet
[P] Electricity meter or fuse box
[W] Openable window
8 716 473 071 (2015/04)
I
c
a
k
j
h
b
T
P
•
The gas heater must not be installed over a heat source.
•
Do not obstruct the openings at top, bottom and rear of
appliance.
•
Maximum of 2 meters from the ground to the base of the
appliance.
•
Top and bottom areas must be clear from any obstacles at
least 30 cm.
j
W
d
n
f
e
T
g
M
9708069951-14.2V
HydroPower