REPAIR INSTRUCTIONS

5. Crimping INOX CLAMP 34

When exchanging BOILER ASSY 36 or DE-AIR VALVE 32 or BRAIDED RUBBER HOSE BOILER 33, it is necessary to
replace the INOX CLAMP 34. Below instructions ensure that the inox clamp is crimped correctly.
Knipex Crimping tool
2.7 mm
(max)
Direct crimp form
CAUTION: When crimping on plastic part like DE-AIR VALVE, avoid over crimping which may lead to plastic part crack.
3.5 mm
(max)
Fold in crimp
GC9240
Inox clamp
Crimping tool
1 - 2 mm
Distance from edge of
crimp to rubber hose
11-12