Swapped Cables Or Configuration Error Detected. A Drive Rearrangement; Swapped Cables Or Configuration Error Detected. An Unsupported Drive Arrangement Was Attempted; Swapped Cables Or Configuration Error Detected. The Cables Appear To Be Interchanged; Swapped Cables Or Configuration Error Detected. The Configuration Information On The Attached Drives - HP ProLiant series Troubleshooting Manual

Hide thumbs Also See for ProLiant series:
Table of Contents

Advertisement

Description: You have exceeded the maximum number of drives supported for this controller, and the
connected controller was not part of the original array configuration.
Action:
Update the controller to the latest firmware version.
1.
If the problem persists:
2.
Replace this controller with the original controller.
or
Replace this controller with a new controller that supports the number of drives in the array.

Swapped Cables or Configuration Error Detected. A Drive Rearrangement...

...was attempted while an expand operation was running. This is an unsupported operation.
SOLUTION: Power down system then move drives back to their original location. Power on system and wait for the
expand operation to complete before attempting a drive rearrangement.
Description: One or more drive locations were changed while an expand operation was in progress.
Action:
Power down the server.
1.
Place the drives in their original locations.
2.
Restart the server, and then complete the expand operation.
3.
Move the drives to their new locations after the expand operation is completed.
4.
Swapped Cables or Configuration Error Detected. An Unsupported Drive
Arrangement Was Attempted...
...SOLUTION: Power down system then move drives back to their original location.
Description: One or more physical drives were moved, causing a configuration that is not supported.
Action: Move all drives to their original locations, and then refer to the server documentation for
supported configurations.
Swapped cables or configuration error detected. The cables appear to be
interchanged...
...SOLUTION: Power down system then move the drives or cables back to their original location.
Description: ADU
configuration. One or more cables may be connected to the incorrect bus or one or more drives have
been moved to new locations.
Action:
Refer to the server documentation for supported configurations and cabling guidelines.
1.
Restore to the original configuration.
2.
Swapped cables or configuration error detected. The configuration information on
the attached drives...
...is not backward compatible with this controller's firmware.
SOLUTION: Upgrade the firmware on this controller. If this doesn't solve the problem then power down system then
move drives back to the original controller.
("Array Diagnostic
Utility" on page 56) has detected a change in the cable
Error messages 81

Advertisement

Table of Contents
loading

Table of Contents