  • Page 1 Thank you very much for purchasing this Air Conditioner. Please read this use and installation instructions carefully before installing and using this appliance and keep this manual for future reference.
  • Page 2: Table Of Contents

    Contents safety instructions Preparation before use Note Preset Safeguarding the envirionment Safety Precautions Identification of parts Indoor unit Outdoor unit Display introduction Remote controller Operation instructions Operation modes Airflow direction control SMART mode CLOCK button SUPER mode TIMER mode QUIET mode ECONOMY mode IFEEL mode DIMMER mode...
  • Page 3: Safety Instructions

    Safety instructions To guarantee the unit work normally, please read the manual carefully before installation, and try to install strictly according to this manual. Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner. Properly ground the air conditioner into the earth.
  • Page 4: Preparation Before Use

    Preparation before use Note When charging refrigerant into the system, make sure to charge in liquid state,if the refrigerant of the appliance is R407C or R410a.Otherwise, chemical composition of refrigerant (R407C or R410a) inside the system may change and thus affect performance of the air conditioner.
  • Page 5: Safety Precautions

    Safety precautions Symbols in this Use and Care Manual are interpreted as shown below. Be sure not to do. Grounding is essential. Warning: Incorrect handling could Pay attention to such a situation. cause a serious hazard, such as death, serious injury, etc. Use correct power supply in accordance with the rating plate requirement.
  • Page 6: Identification Of Parts

    Identification of parts Indoor unit Air Intake Front Panel Emergency Panel Display Panel Air Outlet Vertical Adjustment Louver Horizontal Adjustment Louver Air Filter Remote Controller Air Intake Outdoor unit Pipes and Power Connection Cord Drain Hose Note: Condensate water drains at COOLING or DRY operation.
  • Page 7: Display Introduction

    Display introduction Temperature indicator Display set temperature. It shows FC after 200 hours of usage as reminder to clean the filter. After filter cleaning press the filter reset button located on the indoor unit behind the front panel in order to reset the display.(optional) Running indicator It lights up when the AC is running.
  • Page 8 Display introduction VT series SF series SE series The symbols may be different from these models, but the functions are similar.
  • Page 9 Display introduction UL series Comp. Timer Sleep UQ series UP series Sleep Comp. Timer The symbols may be different from these models, but the functions are similar.
  • Page 10 Display introduction NS series NT series VQ/TE/TF series The symbols may be different from these models, but the functions are similar.
  • Page 11 Display introduction VM series NM series NK series TA/TC series The symbols may be different from these models, but the functions are similar.
  • Page 12 Display introduction VC series Comp. Timer Sleep TD/TG/SA series SC series Emergency button To let the AC run or stop by pressing the button. ON/OFF The symbols may be different from these models, but the functions are similar.
  • Page 13: Remote Controller

    Remote controller Remote controller The remote controller transmits signals to the system. SMART TEMP + - Used to enter fuzzy logic operation directly, regardless of the unit is on or off. Used to adjust the room temperature and the timer, also real time. POWER MODE The appliance will be started when it is...
  • Page 14 Remote controller Remote controller How to Insert the Batteries? Remove the battery cover according to the arrow direction. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Reattach the cover by sliding it back into position. Note: Use 2 LR03 AAA(1.5volt) batteries.
  • Page 15: Operation Instructions

    Operation instructions Operation modes Selecting mode MODE Press button once by once The operation modeis changed in sequence: Result : MODE COOLING FAN ONLY HEATING PRESS Heating mode is NOT available for cooling only air conditioner. FAN mode Press button once by once FAN SPEED Result : The fan speed is changed in sequence:...
  • Page 16: Airflow Direction Control

    Operation instructions Airflow direction control Vertical airflow(Horizontal airflow) is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. Operation mode Direction of airflow COOLING, DRY horizontal *HEATING, downward FAN ONLY PRESS PRESS The direction of airflow can bealso adjusted to your own requirement by pressing the "...
  • Page 17: Smart Mode

    Operation instructions SMART mode How to set SMART mode? SMART Press the button. Result : Enters SMART mode(fuzzy logic operation) directly regardless of the unit is on or off. Temperature and fan speed are automatically PRESS set based on theactual room temperature. Heat pump models Indoor temperature Operation mode...
  • Page 18: Clock Button

    Operation instructions CLOCK button How to adjust the real time? CLOCK Press button. PRESS Result : The time flashes on the LCD. TEMP. Press buttons. TEMP. PRESS Result : Once to increase or decrease the time setting by 1 minute. One and a half seconds to increase or decrease the time setting by 10 minute.
  • Page 19: Timer Mode

    Operation instructions Timer mode It is convenient to set the timer on with TIMER ON/OFF buttons when you go out in the morning to achieve a comfortable room temperature at the time you get home. You can also set timer off at night to enjoy a good sleep.
  • Page 20: Economy Mode

    Operation instructions ECONOMY mode In this mode, the air conditioner will bring you energy saving performance by lower running currency. IFEEL mode The temperature sensor built in remote contronller is activated.It can sense its surrounding temperature,and transmit the signal back the unit,the unit can adjust the temperature so as to provide maximum confort. How to cancel IFEEL mode? i FEEL Press the...
  • Page 21: Sleep Mode

    Operation instructions SLEEP mode SLEEP mode can be set in COOLING ,HEATING or DRYING mode. This function gives you a more comfortable environment for sleep. The appliance will stop operation automatically after operating for 8 hours. Fan speed is automatically set at low speed. How to set SLEEP mode ? SLEEP Each time...
  • Page 22: Maintenance

    Maintenance Front panel maintenance Cut off the power supply Grasp position "a" and Turn off the appliance pull outward to remove the first before disconnecting front panel. from power supply. Never use volatile substance Wipe with a soft such as gasoline or polishing and dry cloth.
  • Page 23: Protection

    Protection Operating condition The protective device maybe trip and stop the appliance in the cases listed below. Outdoor air temperature is over *43 C Outdoor air temperature is over 24 C COOLING HEATING Room temperature is below 21 C Outdoor air temperature is below -10 C Room temperature is below 18 C Room temperature is over 27 C If the air conditioner runs in COOLING or DRY mode withdoor or window opened for a long time when relative...
  • Page 24: Troubleshooting

    Troubleshooting The following cases may not always be a malfunction, please check it before asking for service. Trouble Analysis If the protector trip or fuse is blown. Please wait for 3 minutes and start again, Does not run protector device may be preventing unit to work. If batteries in the remote controller exhausted.
  • Page 25: Installation Instructions

    Installation instructions Installation diagram Distance from ceiling should be over 200 mm Distance from wall should be over 50mm Distance from the wall should be over 50mm Distance from floor should be over 2500mm Air intake distance from the wall should be over 250mm Air intake distance from the wall should be...
  • Page 26: Select The Installation Locations

    Installation instructions Select the installation location Location for Installing Indoor Unit Where there is no obstacle near the air outlet and air can be Indoor unit easily blown to every corner. Where piping and wall hole can be easily arranged. Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page.
  • Page 27: Indoor Unit Installation

    Installation instructions Indoor unit installation 1. Installing the Mounting Plate Decide an installing location for the mounting plate according to the indoor unit location and piping direction. Keep the mounting plate horizontal with a horizontal ruler or dropping line. Drill holes of 32mm in depth on the wall for fixing the plate. Insert the plastic plugs to the hole, fix the mounting plate with tapping screws.
  • Page 28 Installation instructions Piping Joints Thermal Insulation: Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape. wrapped with vinyl type Thermal insulation Piping Thermal Insulation: Large pipe a. Place the drain hose under the piping. Thermal insulation tube b.
  • Page 29 Installation instructions 4. Connecting of the Cable Front panel Terminal (inside) Indoor Unit Connect the power cord to the indoor unit by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit connection. Cabinet Indoor unit Note: For some models, it is necessary to remove the cabinet to...
  • Page 30: Wiring Diagram

    Installation instructions Wiring diagram Make sure that the color of the wires in the outdoor unit and terminal No. are the same as those of the indoor unit. 9K*,12K* Model 9K,12K,18K Model Indoor unit Outdoor unit Indoor unit Outdoor unit Indoor unit Outdoor unit Terminal...
  • Page 31: Outdoor Unit Installation

    Installation instructions Outdoor unit installation Rubber pad (optional) Place under the leg pedestal 1. Install Drain Port and Drain Hose (for heat-pump model only) The condensate drains from the outdoor unit when the unit operates in heating mode. In order not to disturb your neighbor and protect the environment, install a drain port and a drain hose to direct the Washer condensate water.
  • Page 32 Installation instructions How to Purge Air Tubes: (1) Unscrew and remove caps from 2 and 3-way valves. (2) Unscrew and remove cap from service valve. (3) Connect vacuum pump flexible hose to the service valve. (4) Start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes. (5) With vacuum pump still running close the low pressure knob on vacuum pump manifold.
  • Page 33 Version No.1805210-03...