8. Place the RVC onto the drip tray and the water and concentrate chambers
locating under the splitter tubes
9. Dispense Water and Concentrate into the RVC
10. Push the Cancel/Pour button until approx. 300 ~ 350 ml of water has dis-
pensed into the RVC water chamber.
11. Read the RATIO from the RVC
12. Place the RVC onto a flat surface and read both water and syrup volumes.
13. Calculate the Water to Concentrate Ratio.
14. With standard Orange Juice, the Ratio 5 to 1 with a maximum of 5.2 and a
minimum of 4.8.
15. Ratio too low: Increase water flow.
16. To correct too low ratio, increase the water flow.
17. Turn the water flow control screw to the right (clockwise) ¼ turn. Check
the Ratio again by repeating above steps with a new sample in the RVC.
18. Ratio too high: Reduce water flow.
19. Turn the water flow control screw to the left (counterclockwise) ¼ turn.
Check the Ratio again by repeating above steps with a new sample in the
RVC.
© 2013-2015, Cornelius Inc.
- 16 -
Quest Elite QLT 2000
Figure 45.
Figure 46.
Figure 47.
Water ml/
Ratio =
Concentrate ml
Figure 48.
Figure 49.
Publication Number: 620058442