OPERATOR SPECIFICATIONS

This model is intended for use in vehicular slide gate applications:
Usage Classification
Main AC Supply
System Operating Voltage
Accessory Power
Solar Power Max
Maximum Gate Weight
Maximum Gate Travel Distance
Maximum Gate Travel Speed
Maximum Daily Cycle Rate
Maximum Duty Cycle
Operating Temperature
Expansion Board
Inherent Entrapment Protection (Type A)
External Entrapment Protection (Type B1 and/or Type B2)
15-3/16"
INTRODUCTION
Class I & II
120 Vac, .5 Amps (6.5 Amps including Accessory Outlets)
12 Vdc Battery Run / Battery Backup
12 Vdc, 500mA max. for ON + SW (switched)
12 Vdc at 30 watts max.
800 lbs (363.6 kg)
25 feet (7.62 m)
10 inches/second
120 cycles/day
Continuous
Without Heater: -20°C to 60°C (-4°F to 140°F)
With Optional Heater: -40°C to 60°C (-40°F to 140°F)
Optional
Dual - RPM and Current Sense
3 inputs on main board - 3 photoelectric sensors and up to 2 edge sensors
20-3/8"
7.49"
10-1/2"
6
MOUNTING FOOTPRINT
13.65"
.63"