Lab.gruppen D 200:4L Quick Start Manual page 34

D series
Hide thumbs Also See for D 200:4L:
Table of Contents

Advertisement

14. Faults and warnings
Category/Type
PSU
Warning
Warning
Warning
Warning
Warning
Fault
Fault
Fault
Fault
Fault
Fault
Fault
LOAD
Warning
Warning
Warning
34
D SERIES Lake Quick Start Guide rev 2.0.0
Name
On screen text
Under Voltage Limit
Power Average Limit
Breaker Emulation Limit
Mains supply glitch
Upgrade power
supply firmware
Need service
NEED SERVICE:1-8
Mains voltage above
MAINS>400 VPK
400 volt peak
Mains voltage above
270 V
Mains voltage below
65 V
Power supply fault
Check mains
Power supply power protect
PSU POWER PROT
Speaker short
Speaker damaged
SPKR DAMAGED
Under speaker count
UNDER SPKR CNT
Description
The Under Voltage limiter is active as the
mains supply is approaching the lower
UVL ACTIVE
end of the device´s operational voltage.
Output power is decreased to ensure
mains distribution does not collapse
Amplifier is reducing output power due
PAL ACTIVE
to average power or mains current
draw is above safe operating levels
Power supply is reducing mains current
BEL ACTIVE
draw to stay within BEL configured
nominal current and profile
Mains glitch (missing cycles) was
MAINS GLITCH
detected on the mains inlet
Power supply firmware version not
UPGRADE PSU
compatible with amplifier
Power supply internal error
Power supply detects mains voltage
above 400 volt peak. Protective shut
down, auto restart attempt
Power supply detects mains voltage
MAINS>270 V
above operation voltage. Protective
shut down, auto restart attempt
Power supply detects mains voltage
Mains<65 V
below operation voltage. Protective
shut down, auto restart attempt
PSU FAULT
Internal power supply fault
Power supply detects unstable mains
CHECK MAINS
supply. Protective shut down, auto
restart attempt
Too high output power for too low mains
supply voltage. Protective shut down,
auto restart attempt
SPKR SHORT
Both LoadPilot tones below thresholds
One LoadPilot tone is above
or below threshold
Both LoadPilot tones above thresholds
or LoadSmart detected fewer
speakers than expected
Action
Increase mains distribution
stiffness or reduce output
power to avoid limiting
Reduce output power
to avoid limiting
Improve mains distribution
and update BEL
configuration or reduce
output power to avoid
limiting
Check mains distribution/
connection
Upgrade amplifier
firmware
Restart device; if not
cleared it needs service
Check mains distribution/
connection
Check mains distribution/
connection
Check mains distribution/
connection
Check mains distribution/
connection. Restart
device; if not cleared
it needs service
Check mains distribution/
connection
Improve mains supply
voltage or reduce
output power
Check load or calibration
Check load or calibration
Check load and
cabling alibration

Advertisement

Table of Contents
loading

This manual is also suitable for:

D 120:4lD 80:4l

Table of Contents