D SERIES
Rev. 2.0.0
Item no. QSG-DSERIES-LAKE
High-Power installation platform
Lake Variants:
D 200:4L
D 120:4L
D 80:4L
Incorporating technologies from
Quick Start Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D 200:4L and is the answer not in the manual?

Questions and answers

Summary of Contents for Lab.gruppen D 200:4L

  • Page 1 D SERIES Rev. 2.0.0 Item no. QSG-DSERIES-LAKE High-Power installation platform Lake Variants: D 200:4L D 120:4L D 80:4L Incorporating technologies from Quick Start Guide...
  • Page 2: Important Safety Instructions

    1. Important safety instructions 1. Important safety instructions Before using the device, be sure to carefully read the Safety Instructions. Keep this document with the device at all times. 2. Approvals Read these instructions. Keep these instructions Heed all warnings. Follow all instructions.
  • Page 3: Caution

    3. Warnings To completely disconnect this equipment from the AC 3.4.3. Radio interference mains, disconnect the power supply cord plug from the AC A sample of this product has been tested and complies with receptacle. The mains plug of the power supply cord shall the limits for the European Electro Magnetic Compatibility remain readily operable.
  • Page 4 D SERIES Lake Quick Start Guide rev 2.0.0...
  • Page 5 D SERIES Lake Quick Start Guide rev 2.0.0...
  • Page 6 安全に関する注意事項 安全に関する注意事項 本装置を使用する前に、必ず安全のための注意事項をご一読ください。この書類は、常に装置と一緒に保管してください。 注意事項をお読みください。 ネットワーク・ケーブルを使用する場合、US National Differences 注意事項の書類は手の届くところに保管しておいてください。 16.3 項は、VW-1 の難燃対応品を使用することを義務づけています。 全ての警告をお守りください。 規格 全ての指示に従ってください。 本機器は水の近くで使用しないでください。 掃除には、乾いた布のみを使用してください。 換気口は塞がないようにしてください。製造者の指示に従って設置し 本機器は、EMC(European Electro-Magnetic Com- てください。 patibility: EU 電磁両立性)指令 2004/108/EC および ラジエーター、 暖房送風口、 ストーブをはじめ、 熱を発生する機器(ア 低電圧指令 2006/95/EC の必須要求事項に準拠して います。 ンプを含む)の近くに設置しないでください。 有極プラグや接地極付きプラグは安全性を確保するための構造です。 適用規格 : EMC エミッションに関する規制 EN55103- 無効にしないでください。有極プラグは、二本の差し込み刃のうち、...
  • Page 7 警告 電波障害 3.4.3 機器を電源から完全に遮断するには、電源プラグをコンセントから抜いてくだ さい。電源ケーブルの電源プラグは常に容易に抜き差しできるようにしてくだ 本装置のサンプルは European Electro Magnetic Compatibility(EMC)directive さい。 の制限事項に適合するための試験に合格しています。また、本装置は FCC 基準 Part 15 に準ずる Class B デジタル機器の制限事項に適合するための試験に合 Français: Pour démonter complètement l’équipement de l’alimentation 格しています。これらの制限事項は、装置の設置に伴って生じうる有害な電波 générale, démonter le câble d’alimentation de son réceptacle. La prise d’alimentation restera aisément fonctionnelle. 障害からの適切な保護を目的に制定されたものです。本装置は無線周波エネル...
  • Page 8 1. Instructions de sécurité importantes 1. Instructions de sécurité importantes Avant d'utiliser l'appareil, veillez à lire attentivement les instructions de sécurité. Conservez constamment ce document avec l'appareil. 2. Certifications Lisez ces instructions. Conservez ces instructions. Tenez compte de tous les avertissements. Suivez toutes les instructions.
  • Page 9 3. Avertissements Pour totalement isoler l’équipement de l’alimentation secteur, débranchez le cordon d’alimentation de son embase. La fiche This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 secteur du cordon d’alimentation doit rester accessible.
  • Page 10: Wichtige Sicherheitshinweise

    1. Wichtige Sicherheitshinweise 1. Wichtige Sicherheitshinweise Lesen Sie bitte diese Sicherheitsanweisungen sorgfältig, bevor Sie das Gerät verwenden. Bewahren Sie dieses Dokument bitte jederzeit zusammen mit dem Gerät auf. 2. Kennzeichnungen Bitte lesen Sie diese Anweisungen. Bitte bewahren Sie diese Anweisungen auf. Beachten Sie alle Warnhinweise.
  • Page 11 3. Warnungen Um das Gerät vollständig vom Stromnetz zu trennen, müssen Sie den B nach Abschnitt 15. Diese Einschränkungen sollen angemessenen Netzstecker des Gerätes aus der Steckdose ziehen. Der Netzstecker Schutz vor schädlichen Störungen durch elektrische Geräte des Gerätes sollte jederzeit zugänglich sein. gewährleisten.
  • Page 12: Instrucciones Importantes De Seguridad

    1. Instrucciones importantes de seguridad 1. Instrucciones importantes de seguridad Antes de usar este aparato, asegúrese de leer completamente estas Instrucciones de seguridad. Conserve este documento junto con el dispositivo. 2. Certificaciones Lea estas instrucciones. Conserve estas instrucciones Cumpla con lo indicado en los avisos. Siga todas las instrucciones.
  • Page 13 3. Precaución Para desconectar este aparato completamente de la corriente 3.4.3. Interferencias de radio eléctrica, extraiga el enchufe del cable de alimentación de la Se ha verificado que este aparato cumple con los límites salida de corriente. Por este motivo, coloque el cable de forma establecidos por la directiva europea de compatibilidad que siempre pueda acceder a él.
  • Page 14: Table Of Contents

    4. Table of Contents 4. Table of Contents 1. Important safety instructions 2. Approvals 3. Warnings 3.1. Explanation of warning symbols 3.2. Warnings 3.3. Caution 3.4. User responsibility 3.4.1. Mains connection grounding 3.4.2. Speaker output hazard on amplifiers 3.4.3. Radio interference 3.4.4.
  • Page 15 4. Table of Contents 9. Operating voltage 9.1. Low voltage country considerations 10. Grounding 11. Product overview 11.1. Front panel 11.1.1. Additional front panel operations and indications 11.2. Rear panel 12. Signal flow and processing 13. Quick Start Tutorial 13.1. Network setup 13.1.1.
  • Page 16: Introduction

    5. Introduction 5.1. Welcome Thank you for choosing the Lab.gruppen D Series for your sound reinforcement needs. We are confident that you will be pleased with the performance, unique features, configuration flexibility, reliability, and long-term durability offered by this product.
  • Page 17: Feature Summary

    6. Feature summary 6. Feature summary • Four channels with three levels of total available frame power output: 20000 W, 12000 W and 8000 W • Rational Power Management (RPM) • True flexibility in allocating power output across each channel to match requirement, for more efficient use of amplifier inventory •...
  • Page 18: Installation

    Carefully open the shipping carton and check for any damage to the device or the supplied accessories. Every Lab.gruppen product is tested and inspected before leaving the factory and should arrive in perfect condition. If any damage is discovered, please notify the shipping company immediately. Only the consignee may initiate a claim with the carrier or their insurers for damage incurred during shipping.
  • Page 19: Mounting Front Grille

    7. Installation Rear support bracket with mounting hardware Rear support bracket mounted for fixed Rear support bracket mounted for removable installation and bracket pointing forward installation and bracket pointing towards back 7.2.2. Mounting front grille The front grille is shipped on top of the amplifier inside the box to protect it during shipping. The front grille adheres to the amplifier with magnets.
  • Page 20: Cooling And Fan Operation

    8. Cooling and fan operation 8. Cooling and fan operation D Series devices use a forced-air cooling system with airflow from front to rear, allowing high continuous power levels without thermal problems. To facilitate maximum air flow, ensure that no objects such as rack doors or lids are placed at the front or rear of the rack.
  • Page 21: Grounding

    10. Grounding Connecting the amplifier in three phase delta configuration In three-phase configuration where the phases are 120 degrees apart, one can connect three balanced loads in a delta configuration. The connection is made between the phases instead of between the neutral and a phase. 3 phase delta 208V 3 phase Y 120V Three phase delta configuration...
  • Page 22: Product Overview

    11. Product overview 11. Product overview 11.1. Front panel The front panel is consists of an outer front with air intake and a centered user interface. The user interface has LEDs for monitoring and six recessed touch buttons for control. 1 Rack ears for 19 inch rack mount 2 Exterior front grille (also air intake and dust filter holder) USER INTERFACE...
  • Page 23 11. Product overview Table 1 LED/category chart NOTE: See Faults and warnings (pages 23-25) for a detailed description of status, faults and warnings associated with each LED. Green Amber Frame OK Frame warning Frame fault Frame Temp OK Temp warning Temp fault Temp Power supply/...
  • Page 24: Additional Front Panel Operations And Indications

    11. Product overview 11.1.1. Additional front panel operations and indications Frame reset A factory reset and soft reset can be performed from the front panel. A factory reset will restore all settings to original defaults, including network settings, frame presets and current settings. A soft reset reverts only the current settings to default.
  • Page 25: Rear Panel

    11. Product overview 11.2. Rear panel 1 Amplifier Outputs - The amplifier output connectors are sturdy terminal block connectors. See Technical Specifications (pages 26-27) for connector rating. Channels are located from left to right. Each channel has a clearly marked hot (+) and cold (-) terminal 2 Analog Inputs - Analog inputs are available on terminal block connectors with clearly marked hot (+), cold (-) and ground terminals 3 AES3 Inputs - AES3 inputs are available on terminal block connectors with clearly marked hot (+), cold (-)
  • Page 26: Signal Flow And Processing

    12. Signal flow and processing 12. Signal flow and processing The table below is the signal flow diagram for D Series Lake versions. Module Data stored in Module FIles (Speaker Presets) Frame Data stored in System Files and Frame Presets Attenuator ISVPL Mute...
  • Page 27: Quick Start Tutorial

    13. Quick Start Tutorial 13. Quick Start Tutorial This section will describe how to get started with associated software and set up a basic system for operation. 13.1. Network setup 13.1.1. Network connections/topology Each frame has two network ports; a primary and a secondary. See the below diagram for a typical network topology using the primary ports.
  • Page 28: Software Installation And Firmware Update

    13. Quick Start Tutorial 13.2. Software installation and firmware update 13.2.1. Lake Controller software suite 1. The Lake controller software suite includes the Lake controller and accompanying utilities: Lake LoadLibrary, Dante discovery services and CAFÉ. Download the Lake Controller installation from www.labgruppen.com. 2.
  • Page 29: System Setup

    13. Quick Start Tutorial 13.3. System setup This tutorial provides a step-by-step guide for configuration of a typical professional loudspeaker system and provides an overview of the basic features and operation of the frame. This tutorial describes how to configure 4-channel frame for use with a generic 3-way loudspeaker system (with separate HF, MF and LF drivers), plus a separate subwoofer.
  • Page 30 13. Quick Start Tutorial Bridge Bridge 14. The B module is already a CL1way as default and can be used to drive the sub. 15. Tap Store/Recall EXIT to return to the Modules Menu. 16. Ensuring Module A (or any other module that you want to control) is selected (yellow border), tap I/O Config. 17.
  • Page 31 13. Quick Start Tutorial Levels Control - Drag sliders and tap mute buttons for module Parametric EQ control – Select filter on the top squares input and output channels. and adjust filter properties by dragging the controls. Sliders at the bottom control center frequency and Q (bandwidth). Gain is controlled in the main window area.
  • Page 32 13. Quick Start Tutorial 21. Repeat step 16 and 20 for the B module. On the Output EQ/Crossover, tap the Aux Output Functions button on the menu bar and then tap LPF Enable button. Drag the Low pass filter control object on the frequency slider just above the menu bar to an appropriate crossover frequency for the sub, e.g.
  • Page 33: Faults And Warnings

    14. Faults and warnings 14. Faults and warnings Category/Type Name On screen text Description Action FRAME Check network cabling/ Frame unable to find Lake controller Lake Controller offline CTRL OFFLINE network if controller Warning on the network expected on the network Frame not able to lock to Check AES sender and AES clock slipping...
  • Page 34 14. Faults and warnings Category/Type Name On screen text Description Action The Under Voltage limiter is active as the mains supply is approaching the lower Increase mains distribution Under Voltage Limit UVL ACTIVE end of the device´s operational voltage. stiffness or reduce output Warning Output power is decreased to ensure power to avoid limiting...
  • Page 35 14. Faults and warnings Category/Type Name On screen text Description Action LoadSmart detected more speakers Check load and More speakers OVR SPKR COUNT Warning than expected cabling or fingerprint Check load and Uncertain about load UNCERTAIN LOAD LoadSmart uncertain about load Warning cabling or fingerprint Perform LoadSmart...
  • Page 36: Technical Specifications

    15. Technical Specifications 15. Technical Specifications D 200:4L D 120:4L D 80:4L General Processing / Network Lake / Dante Numbers of amplifier channels Total burst power all channels (share among channels with RPM) 20000 W 12000 W 8000 W Max. Output Power (all ch.’s driven)
  • Page 37 Approvals CE, ETL (ANSI/UL, CSA), PSE, RCM Note 1): Lab.gruppen burst power (1 kHz, 25 ms burst power @ 150 BPM, 12 dB Crest factor) All specifications are subject to change without notice. D SERIES Lake Quick Start Guide rev 2.0.0...
  • Page 38: Warranty And Support

    Lab.gruppen dealer. If the product fails to perform as specified during the warranty period, Lab.gruppen will undertake to repair, or at its option, replace this product at no charge to its owner, provided the unit is returned undamaged, shipping prepaid, to an authorized service facility or to the factory.
  • Page 39: Factory Service

    16. Warranty and support 16.2.2. Factory service In the event a Lab.gruppen product requires factory service, you may contact Lab.gruppen’s service department for return instructions and a Return Authorization number. Please note for product return: 1. Use the original packing.
  • Page 40 RPM, R.SMPS, PFC, CDM, BEL, UVL, CAFÉ, ESP, ISVPL, Iso-Float, Raised Cosine, MESA EQ, LimiterMax and LoadLibrary are trademarks of Lab.gruppen AB. All other trademarks remain the property of their respective owners. Copyright © 2015 Lab.gruppen AB. All rights reserved.