Table 1 LED/category chart
NOTE: See Faults and warnings (pages 23-25) for a detailed description of status, faults and warnings associated
with each LED.
Frame
Temp
PSU
No mains power
Power
No LoadPilot active
Load
Amp
Signal below signal
Signal
present threshold (-60 dB)
Inactive channel in
Mute
bridge operation
Frame not selected
Select
OFF
Green
N/A
Frame OK
N/A
Temp OK
N/A
PSU OK
Fixed:ON
Blinking: Turning ON
LoadPilot active
and LoadOK
N/A
Power channel OK
Signal above signal
present threshold (-60 dB)
Unmuted
Frame selected
Amber
Frame warning
Temp warning
Power supply/
Mains warning
Button pressed.
Hold for transition
Load warning
Power channel warning
Signal approaching
input clip (-2 dB)
Lake module is muting the
signal chain at either input
Power channel muted
router, module input or
module output
Waiting for more touches
D SERIES Lake Quick Start Guide rev 2.0.0
11. Product overview
Red
Frame fault
Temp fault
Power supply/
Mains fault
Fixed: STANDBY
Blinking: Turning to
STANDBY
Load fault
Power channel fault
Signal clip
or limit/fault active
N/A