Function Tests 
Protective insulation test (1) 
Perform the protective earth conti­ 
nuity test at first, if it is mandatory. 
What is the protective insulation test 
about? 
This test is necessary 
­  for class 1 and 2 equipment (with/without 
protective earth), 
­  after a repair whenever the housing was 
opened and for example a general disas­ 
sembly was performed. 
General 
Legal regulation 
In case of a repair/modification of the coffee 
machine, the repair centre is bound by law to 
protect the user/consumer by 
­  restoring the regular condition of the appli­ 
ance and 
­  performing the respective tests according 
to EN/IEC 60335­1 "Safety of household 
and similar electrical appliances" and 
national regulations (e.g. DIN VDE 0701). 
Description 
The insulation test 
­  assures that wiring and insulation of the 
coffee machine fullfill the normative 
Service Manual C91 / D91 
requirements after a repair, 
­  rates the insulation capability of the coffee 
machine, 
­  is a very dangerous test because of a high 
test voltage (500 V DC). 
For the insulation test, phase and neutral wire 
are shunted at the power plug. Then a test 
voltage is applied between phase/neutral and 
selected parts of the coffee machine. 
Test equipment 
Special test equipment is needed that 
complies  with the regulations to perform insu­ 
lation and withstanding voltage tests. Detailed 
requirements and tolerances must be verified 
with your local authorities or measurement 
supplier in any case. 
Ideally the test equipment has a national 
power socket for testing, so that the coffee 
machine can plugged in directly. Otherwise a 
special shunt is necessary to connect the 
phase and neutral pin of the coffee machine's 
power plug. 
 Nespresso
Ask
 for recommenda­ 
tions about test equipment. 
30 
Test report 
For legal reasons a repair or test report should 
be prepared and filed with following informa­ 
tion 
­  customer (name, address) 
­  type and serial number of coffee machine 
­  date of repair/test(s) 
­  performed test(s)/measuring value(s), test 
points 
­  used test equipment 
­  signature 
Test sequence 
Danger of electrical shock/short 
circuit! 
•  Do not plug in the coffee machine 
during insulation test. 
Danger of electrical shock! 
•  Do not touch tip of test probes. 
•  Do not touch metallic parts of coffee 
machine during test. 
•  Read and observe safety instructions 
in user manual of test equipment. 
Continued on next page.