Protective Insulation Test (1) - Nespresso Essenza EF 347 Service Manual

Table of Contents

Advertisement

Function Tests

Protective insulation test (1)

Perform the protective earth conti-
nuity test at first, if it is mandatory.
What is the protective insulation test
about?
This test is necessary
-
for class 1 and 2 equipment (with/without
protective earth),
-
after a repair whenever the housing was
opened and for example a general disas-
sembly was performed.
General
Legal regulation
In case of a repair/modification of the coffee
machine, the repair centre is bound by law to
protect the user/consumer by
-
restoring the regular condition of the appli-
ance and
-
performing the respective tests according
to EN/IEC 60335-1 "Safety of household
and similar electrical appliances" and
national regulations (e.g. DIN VDE 0701).
Description
The insulation test
-
assures that wiring and insulation of the
coffee machine fullfill the normative
Service Manual EF 347 / EF 348
requirements after a repair,
-
rates the insulation capability of the coffee
machine,
-
is a very dangerous test because of a high
test voltage (500 V DC).
For the insulation test, phase and neutral wire
are shunted at the power plug. Then a test
voltage is applied between phase/neutral and
selected parts of the coffee machine.
Test equipment
Special test equipment is needed that complies
with the regulations to perform insulation and
withstanding voltage tests. Detailed require-
ments and tolerances must be verified with
your local authorities or measurement supplier
in any case.
Ideally the test equipment has a national
power socket for testing, so that the coffee
machine can plugged in directly. Otherwise a
special shunt is necessary to connect the
phase and neutral pin of the coffee machine's
power plug.
3 7
Test report
For legal reasons a repair or test report should
be prepared and filed with following informa-
tion
-
customer (name, address)
-
type and serial number of coffee machine
-
date of repair/test(s)
-
performed test(s)/measuring value(s), test
points
-
used test equipment
-
signature
Test sequence
Danger of electrical shock/short
circuit!
Do not plug in the coffee machine
during insulation test.
Danger of electrical shock!
Do not touch tip of test probes.
Do not touch metallic parts of coffee
machine during test.
Read and observe safety instructions
in user manual of test equipment.
Continued on next page.
Version 1.0
en

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Essenza c99Essenza ef 348Essenza d99

Table of Contents