3. SETUP

Fuse Replacement

With a fl at head screwdriver, wedge the
fuse holder out of its housing. Remove the
damaged fuse from its holder and replace
with exact same type fuse. Insert the fuse
holder back in its place and reconnect
power.

Connecting A Bunch of G60's™

You will need a serial data link to run light shows using a DMX-512
controller or to run shows on two or more fi xtures set to sync in mas-
ter/slave operating mode. The combined number of channels required
by all the fi xtures on a serial data link determines the number of fi x-
tures the data link can support.
Fixtures on a serial data link must be daisy chained in one single line.
Also, connecting more than 32 fi xtures on one serial data link without
the use of a DMX optically-isolated splitter may result in deterioration
of the digital DMX signal.
The maximum recommended cable-run distance is 500 meters (1640
ft). The maximum recommended number of fi xtures on a serial data
link is 32 fi xtures.
Data/DMX Cabling
To link fi xtures together you'll need data cables. You should use data-
grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.
For instance, Belden© 9841 meets the specifi cations for EIA RS-485
applications. Standard microphone cables will "probably" be OK, but
note that they cannot transmit DMX data as reliably over long distanc-
es. In any event, the cable should have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor & shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms
G60™ Manual Rev. A
Page 7
Copyright (c) 2011 Blizzard Lighting, LLC