Refrigerant Leakage Detection Diagnosis And Solution(Ec) - Midea MSMBB-12CRDN1-MP0W Service Manual

Mission mini split 3d dc inverter air conditioner
Table of Contents

Advertisement

9.3.6 Refrigerant Leakage Detection diagnosis and solution(EC)

Error Code
Malfunction decision
conditions
Supposed causes
Trouble shooting:
EC
Define the evaporator coil temp.T2 of the compressor just starts
running as Tcool.
In the beginning 5 minutes after the compressor starts up, if T2
°C(
<Tcool-2
Tcool-35.6
seconds and this situation happens 3 times, the display area will
show "EC" and AC will turn off.
T2 sensor faulty
Indoor PCB faulty
System problems, such as leakage or blocking.
°F)
does not keep continuous 4
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msmbc-18crdn1-mp0wMsmbd-22crdn1-mp5w

Table of Contents