4
Compressor
parts.
1)
Perform work of item
1,2.
2)
Remove the two
connectors for the compressor
and the reactors.
3)
Remove two blue wires
connected with the four way
valve.
4)
Remove the connectors
for the condenser coil temp.
sensor(T3),outdoor ambient
temp. sensor(T4) and
discharge temp. sensor(T5).
(two black connectors, one
white connector)
5)
Remove the ground
wires .
6)
Remove the fixing screws.
7)
Remove the electronic
control box.
How to remove the
compressor.
64
②
③
④ T3,T4,T5
⑤
⑥
two screws