Section: 3 The Direct Vent System; Section 3-1: Converting To Top Vent / Rear Vent - Montigo H38DF-CLCR Installation & Maintenance Manual

Indoor corner unit residential gas fireplace
Table of Contents

Advertisement

H*38DF-CLCR Corner Gas Fireplace

Section: 3 The Direct Vent System

Montigo supplies a variety of direct venting and termination options.
The direct vent termination location MUST be selected such that
it is the highest point in the venting assembly� It should also be
selected such that it provides the shortest vent run possible. Should
it be impossible to ensure that the termination is the highest point or
should it be impossible to meet the venting guidelines laid out below
please contact your Montigo dealer to discuss power venting options.
NOTES FOR PLANNING VENTING:
Venting originates from the unit through the top or through
the rear
Venting can terminate through the roof or through an
exterior wall.
Refer to Appendix A - Termination Locations to ensure the
planned termination location is acceptable�
Once the termination location has been established, refer
to the appropriate section below for installation details
All fireplaces shipped from the factory are Top vent.
Silicone application is NOT required when joining Montigo
vent pipes and components�

Section 3-1: Converting to Top Vent / Rear Vent

Use the following instructions to convert an H*38C* for Rear Vent use:
1. Remove the Rear flue cover and gasket (5" and 8") on the flue
outlet, as shown in Figure 8�
2. Next, Remove the Top flue collar's (5" and 8") on the flue outlet,
as shown in Figure 8�
Flue Gasket
Flue Cover Plate
Figure 8. Flue cover and collar removal, Top Vented fireplace.
Page 10
Installation
3. Install the (removed) Rear flue cover and gasket material, to the
4. Install the (5" and 8") collars to the rear vent outlet using the
Figure 8a. Flue cover and collar installation, Rear Vented fireplace.
Note: Images are shown without screens for clarity purposes. However,
your fireplace should not be operated without proper installation of
screens.
5" Inner Flue Collar
8" Outer Flue Collar
Top vent outlet. Fasten the cover with included hardware, as
illustrated Figure 8a.
included hardware, as illustrated Figure 8a.
8" Outer Flue Collar
5" Inner Flue Collar
Flue Cover Plate
Flue Gasket
XG0213 - 150204.2