Viking VS 3725 Installation Manual page 13

2-way lcd pager alarm with remote engine starter
Table of Contents

Advertisement

5. Finish by turning the ignition switch to "On" position.
REMOTE START FEATURE PROGRAM MODE.
1. Turn the Ignition switch 'On then Off 3 TIMES and stay in Off position.
2. Within 10 seconds, push and release the Valet switch 6 times and holding in on the 6
long chirp from siren to confirm you are now in the start feature programming mode.
Press
Press and
One Chirp /
release
LED one pulse
Valet
Factory Default
Switch
Setting
One time
Gasoline Engine
Two times
10 minutes run time
Three times
Engine Checking
TACH. / RPM
learning mode.
Four times
Start Timer for
Voltage checking
type:
0.6-second
Five times
Low check level
Six times
Factory alarm
disarm with
channel 3 on
Seven
Constant parking
times
light output
Eight times
Door lock before
start
Nine times
White / Blue Wire =
1 pulse activate
Ten times
Brown / White Wire
= (-) 200mA Horn
Output
Eleven
Temperature-Contr
times
ol Starting OFF
Twelve
The Vehicle without
times
Turbo
Thirteen
Fahrenheit display
times
for temperature
Exit:
Turn Ignition to 'ON' position, or leave it for 15 seconds. A 3 long chirps & 3 parking light flashes to
confirm exit.
Important Note: The voltage "Check Level" for most vehicles would be set in "Hi Check Level", while in
"Engine Check Voltage" mode, the "Check Level" must be set at "HI" position first.
ENGINE CHECKING TACH. / RPM LEARNING
1. Turn the Ignition switch 'On then Off 3 TIMES and stay in Off position.
2. Within 10 seconds, push and release the Valet switch 6 times and holding in on the 6
long chirp from siren to confirm you are now in the start feature programming mode.
3. Within 10 seconds, press and release the valet switch 3 times again, 3 chirps to confirm the system in
features "Engine Checking TACH or Voltage" mode.
VS3725IN
button
Press
Two Chirps /
LED two pulses
Diesel Engine without
Wait-To-Start Light
10 seconds warn-up
timer
20 minutes run time
Engine Checking
Voltage
Start Timer for
Voltage checking
type:
0.8-second
Hi check level
Without this feature
Flashing parking light
output
Door lock after
shut-down
White / Blue Wire =
2 pulse activate
Brown / White Wire =
Factory Security
Rearm Signal Output
Temperature-Control
Starting 5F (-15C)
Built-in Turbo Timer
Control is Active:
Press
and
buttons at the same
time to control
Engine running one
minute.
Celsius display for
temperature
button
Press
Three Chirps /
LED three pulses
Diesel Engine without
Wait-To-Start Light
15 seconds warn-up
timer
30 minutes run time
Start Timer for
Voltage checking
type:
1.0-second
Door lock before
start and Door lock
after shut-down
Temperature-Control
Starting – 4F (-20C)
Built-in Turbo Timer
Control is Active /
Press
and
buttons at the same
time to control
Engine running
three minutes.
13
FEBERARY/06/2006
th
push until two
button
Press
button
Four Chirps /
LED four pulses
Diesel Engine without
Wait-To-Start Light
20 seconds warn-up
timer
5 minutes run time
4 chirps = 1.2-second,
5 chirps = 1.4-second,
6 chirps = 1.6-second,
7 chirps = 1.8-second,
8 chirps = 2.0-second,
9 chirps = 3.0-second,
10 chirps = 4-second,
Without this feature
Temperature-Control
Starting – 22F(-30C)
Built-in Turbo Timer
Control is Active /
Press
and
buttons at the same
time to control
Engine running five
minutes.
th
push until two

Advertisement

Table of Contents
loading

Table of Contents