Bradford White UCG100H199 Installation & Operation Manual page 46

Gas-fired commercial water heater
Table of Contents

Advertisement

Display of Water Temperature
Step 1: In Service Mode, Press the "Select" button until "Water Temp" is displayed in the upper right section of
the water heater display.
To Display Flame Sense Current of the Pilot Flame Sensor
The pilot flame sense current is available only when the burners are in operation. Step 1: Make sure the
status displays "Heating" or draw enough hot water to start the burners. Step 2: Enter the "Service Mode"
described previously. Step 3: Press the "Select" button until a number value is displayed with "Flame Current"
to the right of the number. The value displayed is in microamps (µA).
This is the reading for the tank sensor.
Status
SELECT
Heating
Status Operational
SELECT
Water
°F
Temp
idle
Operational
SET
Flame
Current
µA
SET
46