2.1. Burning up
1. Pour the pellets into the hopper and tightly close the lid.
2. Connect the main power plug into the 230V/50 socket.
ATTENTION!
Socket should be protected with min. 10A fuse and 20 mA RCD (residual current
device).
3. Start the controller.
To start the controller it is necessary to press the „ON/OFF/ESC" button for 3 seconds. The same
operation with turning off the controller. Present status is shown on the display:
OFF – (active control of alarm parameters, manual mode of blower and feeder)
ON
ATTENTION!
When „OFF" is shown on the display device is in standby mode and is still live. In
case of alarm controller will activate all pumps or feeders.
ATTENTION!
It is forbidden to use for boiler lightning up any flammable substances.
If boiler is in idle time or maintenance is made it's essential to unplug the boiler from the main power.
Display shows current state of individual devices. Picture shows main menu view.
Pic. 2. Main display.
Last line on display shows through abbreviations active devices.
ABBR.
HP
central heating pump operation
WP
hot water pump operation
BU
buffer pump operation
LIG
heating element operation
fee
feeder operation
fa 20
blower operation, current blower output
M0
mixing valve closing
M1
mixing valve opening
Tab 1. Abbreviation table with devices names.