[RAM Test]
RAM Test uses, as the test area, all areas except for the program and system areas. USER area
is not guaranteed after performing the test.
RAM 64MByte
0x0000000
Area for BOOTER
0x0030000
Program/system area
USER area
0x3FDFFEF
Timer
0x3FFFFFF
[FROM Test for Hibernation]
FROM test for hibernation tests all areas.
Do not turn off the power during the test. If a power fails during the test, the hibernation function is
launched and this FROM is used.
Therefore the test which was being performed may be unsuccessful.
If the power is turned off without any backup battery, the hibernation function does not operate
FROM 64MByte (128KByte × 512 blocks)
0x0000000
System area
0x0020000
Backup area
0x3FFFFFF
Scope of READ ONLY Test
Scope of WRITE/READ Test
The sizes vary according to
the program and system capacities.
Scope of the test in this range
CLEAR Test
READ ONLY Test
WRITE/READ Test
— 44 —