7-4. Status Information
Shows a screen as shown below on the LCD (XGA).
(In this chapter, the area for entries and the area for test results are illustrated separately.)
MAC ADRS
XX-XX-XX-XX-XX-XX
TEMP
20
VOLTAGE
XX
DISP ON/OFF
ON
Diag Ver : XXXXXX XXXX
DALLAS
DRW
1CLOSE
2CLOSE
0000
Counter display
[Function]
Displays the status of each device.
Device
DALLAS
DRW 1/DRW 2
CHARGE-MODE
TEMP/VOLTAGE
PANEL SIZE
CF
MAC ADRS
DISP ON/OFF
CHARGE-MODE 360M
CF
INSERT
PANEL SIZE 15"
1234
Indicates DALLAS key No. in a hexadecimal value
Indicates open/close status of the drawer.
OPEN: Drawer is open
CLOSE: Drawer is closed
Indicates the remaining amount of the battery in minutes.
nM: Remaining battery (minutes) n=0 ~ 360
TEMP/VOLTAGE Indicates the A/D value of the battery.
DISP ON/OFF: The acquisition of TEMP status is prioritized when
the switch is ON.
Be sure to turn off DISP ON/OFF switch before opening other status
information or starting the Test Mode.
PANEL SIZE: Indicates the panel size.
15": Enhanced model (15-inch panel)
12": Junior model (12-inch panel)
CF: Indicates whether a CF Card is inserted.
INSERT: CF Card is inserted
NON: CF Card is not yet inserted.
MAC ADRS: MAC address written on FLASH ROM is indicated in a
hexadecimal value.
To write in FLASH ROM, use the MAC Address Writing function of
this DIAG.
The default is set to ON.
ON/OFF may be switched in the software setting.
— 42 —
Status information is displayed continuously
(in ordinary characters). However,
when performing a test, the status at
completion of a test is displayed
following completion of that test.
Status information (description of messages)