Casio EX-830 Service Manual page 45

Table of Contents

Advertisement

7-5. Memory Test Overview
7-5-1.Types of memory tests
READ ONLY Test
CLEAR & WRITE/READ Test
CHECK SUM Test
7-5-2. Scope of memory tests
[FROM Test]
This program does not back up programs or data. Be sure to perform IPL after performing CLEAR
and/or WRITE READ Test.
The data contained in the area used to perform CLEAR or WRITE Test is not protected.
In order to perform CLEAR or WRITE/READ Test, the program and data are copied as backup
temporarily in an available area of RAM.
Do not turn OFF the power during the test. Doing so may destroy the program and the proper
operation cannot be guaranteed. Should this occur, all operations, starting IPL, must be
performed.
FROM 32MByte (128KBytes × 256 blocks)
0x0000000
BOOTER, Protected data area
0x0100000
Program
FILE data
Free area
0x1FFFFFF
RAM
(for programming)
WRITE Test
CLEAR Test
Scope of the test in this range
• CLEAR&WRITE/READ Test
• READ ONLY Test
• WRITE/READ Test
— 43 —
FLASH ROM
FLASH ROM
(for hibernation)
Scope of the test in this range
• Sum check
CF