Limited warranty

This product comes with limited warranty commencing on the date of purchase (See warranty card
for details). Within the warranty period we will eliminate, free of charge, any defects in the appliance
resulting from faults in materials or workmanship, by replacing the complete appliance.
This warranty is applicable only for the appliance supplied by the appointed distributor. This warranty
does not cover: damage due to improper use, normal wear or use as well as defects that have a
negligible effect on the value or operation of the appliance. The warranty becomes void if repairs are
undertaken by unauthorized persons and if original Braun parts are not used.
guidance and manufacturer's declaration – electromagnetic emissions
The IR thermometer equipment is intended for use in the electromagnetic environment specified below.
The customer or the user of the IR thermometer should assure that it is used in such an environment.
Emissions Test
compliance
Electromagnetic environment – guidance
The ME equipment uses RF energy only for it's internal func-
RF Emissions
Group 1
tion. Therefore, its RF emissions are very low and are not likely
CISPR 11
to cause any interference in nearby electronic equipment.
RF Emissions
Class B
Complies
CISPR 11
Harmonic emissions
Not Applicable
IEC 61000-3-2
The ME equipment is
solely battery powered.
Voltage fluctuations /
Not Applicable
flicker emissions
guidance and manufacturer's declaration – electromagnetic immunity
The IR thermometer is intended for use in the electromagnetic environment specified below.
The customer or the user of the IR thermometer should assure that it is used in such an environment.
IEc60601 test
Immunity test
level
Electrostatic discharge
±6kV Contact
(ESD)
±8kwww Air
IEC 61000-4-2
12
Electromagnetic environment
compliance level
– guidance
Floors should be wood, con-
crete, or ceramic tile. If floors
Complies
are covered with synthetic
material, the relative humidity
should be at least 30%
Radiated RF
3 V/m 80MHz to
2.5GHz
IEC 61000-4-3
Conducted RF
3Vrms 150kHz to
80MHz
IEC 61000-4-6
Electrical fast transient
±2kV power line
IEC 61000-4-4
±1kV I/O lines
±1kV
Surge
differential
IEC 61000-4-5
±2kV common
Power frequency magnetic
field
3 A/m
IEC 61000-4-8
>95% dip 0.5
Voltage dips, short
cycle
interruptions and voltage
60% dip 5 cycles
variations on power
70% dip 25
supply input lines
cycles
IEC 61000-4-11
95% dip 5 sec.
non-Life support Equipment separation distance calculation
(3Vrms / 3V/m compliance)
Separation distance according to frequency of transmitter (m)
150 kHz to 80 MHz
Rated maximum output
in ISM bands
power of transmitter (W)
3.5
d = [
] P
V
1
0.01
0.12
0.1
0.37
1
1.17
10
3.69
100
11.67
Field strengths outside the
shielded location from fixed RF
Complies
transmitters, as determined by
an electromagnetic site survey,
should be less than 3 V/m.
Interference may occur in the
vicinity of equipment marked
with the following symbol:
Not Applicable
(no electrical
Separation distance calculation
cabling)
provided above. If a known
transmitter is present the
specific distance can be
calculated using the equations.
Not Applicable
The ME equipment
is solely battery powered.
Not Applicable
Power frequency
magnetic fields should be at
levels characteristic of a
Complies
typical location in a typical
commercial or hospital
environment.
The ME equipment
Not Applicable
is solely battery
powered.
80 MHz to
800 MHz to 2.5 GHz
800 MHz
3.5
7
d = [
] P
d = [
] P
E
E
1
1
0.12
0.23
0.37
0.74
1.17
2.33
3.69
7.38
11.67
23.33
13