Section 2-Generator Won't Start; Section 3-No Start, No Spark - BOLIY PRO3600SI User Manual

Hide thumbs Also See for PRO3600SI:
Table of Contents

Advertisement

Section 2-
1-No Start, Cranks, has spark & fuel.
2- Choke pin. It's possible that the choke pin that fell out. Look under the choke plate for a pin operating
the choke mechanism. If not, change the choke plate and thechoke cable.
Section 3-
1-
No Start, Cranks, has no spark.
Do you hear a click when you turn the engine switch to on?
If no, the micro switch is not operating properly. It could be a wire stopping it from moving or could be dirty. Clean
with a non flammable pressurized cleaner like electrical contact cleaner. If it still doesn't operate, change the
micro switch.
2-
Low Oil Switch. It could be the low oil switch if the low oil light is coming on and the unit will not start. The
oil switch might be stuck. 1- Check the oil level. 2- Unplug the oil switch and run the engine for 2 minutes. 3-
Reconnect the oil switch with the engine running. 4- Check for a damaged wire (shorting to ground).
3
- Ignition Windings. It could be the ignition system. Remove the control panel you will see 4 pin connector.
Yellow/Green-Red 0.7~0,85 .
5
- Ignition Coil.To check the primary side of the ignition coil, check continuity between ground and blue wire. To
check the secondary side of the ignition coil, unplug the spark plug wire and check continuity between the blue
wire and spark plug wire. There should be a reading between 12.0 and 20.0 k-ohms. If either or both of these are
faulty, there could be a loose wire or bad ignition coil.(2 should to background)
Resistance of trigger 15~20Ω
2
1-3(190~210Ω)
23