Emergency Power Consumption - Dražice OKC 100 NTR Operation And Installation Manual

Tank type indirect water heaters
Table of Contents

Advertisement

Advantages of using indirect heater
Easy installation and connection to heating water supply,
very fast HSW heating,
enamelled steel tank ensures all hygienic requirements on the quality of HSW,
built-in Mg anode increases resistance to corrosion,
good quality polyurethane insulation ensures minimum thermal losses,
continuously adjustable temperature of HSW up to 74°C,
connection of multiple withdrawal points,
the type with two heat exchangers can use two heating water supplies, or double heat
transfer surface can be obtained if those are combined,
heater operation control light,
accurate check of HSW temperature,
possibility of connecting HSW circulation.

1.2.3 EMERGENCY POWER CONSUMPTION

If no heated water is taken from the tank, a small amount of heat leaks. This loss is
measured for a period of 24 hours at the temperature of 65°C in the heater, and at 20°C in
its ambient area. The resulting value is expressed in [kWh/24h] and indicates the amount of
power needed to maintain the set temperature. Data Sheet pursuant to Directive No - see
Table 1.
HEATING
TYPE
WATER FLOW
(l/h)
OKC 100 NTR
OKC 125 NTR
OKC 160 NTR
720
OKC 200 NTR
OKC 250 NTR
OKC 200 NTRR
OKC 250 NTRR
Table 1
PRESSURE
HEAT LOSSES
LOSS (mbar)
kW/24h
33
46
2 x 33
61
- 5 -