Electric Wiring; Electric Installation General Information; Methods Of Electronic Thermostat Connection - Dražice OKC 100 NTR Operation And Installation Manual

Tank type indirect water heaters
Table of Contents

Advertisement

2.4 ELECTRIC WIRING

2.4.1 ELECTRIC INSTALLATION GENERAL INFORMATION

Check the insertion of the thermostat sensor in the thermowell, the so-called
insertion all the way.
The heater can be connected to any hot water heating boiler up to the power output
of 50 kW.
Electrically, the heater is powered directly by boiler with 230 V/50 Hz control
voltage.
To adjust the distance from the wall, connect the wire of the external protective
bonding!
Elastic cable CYSY 4C x 0.75 can be used for interconnection.
Connecting terminals are identified on the terminal board of the heater.

2.4.2 METHODS OF ELECTRONIC THERMOSTAT CONNECTION

Electric connection to heaters of the below types: OKC 100 NTR, OKC 125 NTR, OKC 160 NTR, OKC 200
NTR, OKC 200 NTRR, OKC 250 NTRR, OKC 100 NTR/HV, OKC125 NTR/HV, OKC160 NTR/HV
Figure 14
Touch thermometer is installed on the control panel to control the temperature of water,
additionally there is a capillary thermostat to set the desired water temperature and two
signal lights: "green" – heater heated, and "orange" – heating in process.
Electric connection to heaters of the below types: OKC 80 NTR/Z, OKC 100 NTR/Z, OKC 125 NTR/Z, OKC
160 NTR/Z, OKC 200 NTR/Z, OKCV 125 NTR, OKCV 160 NTR, OKCV 180 NTR, OKCV 200 NTR
- there is voltage on connecting terminal 2 when heater is
heated
- there is voltage on connecting terminal 1 when heater is
not heated
- 22 -