2.4 ELECTRIC WIRING
2.4.1 ELECTRIC INSTALLATION GENERAL INFORMATION
•
Check the insertion of the thermostat sensor in the thermowell, the so-called
insertion all the way.
•
The heater can be connected to any hot water heating boiler up to the power output
of 50 kW.
•
Electrically, the heater is powered directly by boiler with 230 V/50 Hz control
voltage.
•
To adjust the distance from the wall, connect the wire of the external protective
bonding!
•
Elastic cable CYSY 4C x 0.75 can be used for interconnection.
•
Connecting terminals are identified on the terminal board of the heater.
2.4.2 METHODS OF ELECTRONIC THERMOSTAT CONNECTION
Electric connection to heaters of the below types: OKC 100 NTR, OKC 125 NTR, OKC 160 NTR, OKC 200
NTR, OKC 200 NTRR, OKC 250 NTRR, OKC 100 NTR/HV, OKC125 NTR/HV, OKC160 NTR/HV
Figure 14
Touch thermometer is installed on the control panel to control the temperature of water,
additionally there is a capillary thermostat to set the desired water temperature and two
signal lights: "green" – heater heated, and "orange" – heating in process.
Electric connection to heaters of the below types: OKC 80 NTR/Z, OKC 100 NTR/Z, OKC 125 NTR/Z, OKC
160 NTR/Z, OKC 200 NTR/Z, OKCV 125 NTR, OKCV 160 NTR, OKCV 180 NTR, OKCV 200 NTR
- there is voltage on connecting terminal 2 when heater is
heated
- there is voltage on connecting terminal 1 when heater is
not heated
- 22 -