Handling and operation
GB
Charging batteries
MT
18
In this chapter you will receive important information for the handling and opera-
tion of the device.
♦
Place the device on a smooth, level and slip resistant surface.
♦
Compare the technical details with those of your power supplier. If they
match, insert the plug into a mains power socket. The LEDs light up in red
three times. The battery charger is now ready for use.
♦
Insert the batteries into the charging slots. Press the 9 V Block batteries
into the charging slot until they audibly engage.
NOTICE
►
1 to 8 batteries can be individually charged:
- 4 x Type C or Type D batteries in the charging slots 1 to 4, with additionally
2 x Type 9 Volt Block batteries in the charging slots 5 and 6
or
- 6 x Type AA or AAA in the charging slots 1 to 4 and additionally
2 x Type 9 Volt Block batteries in the charging slots 5 and 6.
♦
The charging process now begins. The battery charger has an LED for each
compartment in the charging slot. The LEDs of the respective charging slots
show the charge status of the individual batteries. In addition, the charge
status is also indicated on the display.
During the fi rst 5 seconds the battery charger carries out a capacity test:
LED Colour
Green
Orange
Red
NOTICE
►
If the LED on the charging slot blinks red for longer than 5 seconds and
the complete battery symbol in the display
improperly inserted into the loading slot or it is defective.
♦
When the battery capacity has been determined, the charging process begins.
Capacity of the
battery
High
Medium
Low
fl ashes, the battery is either
4
Display indication
TLG 1000 C4