Electric Connection - Lacanche SULLY CHALONNAIS LG 1432 GE Installer Manual

Sully chalonnais
Table of Contents

Advertisement

The cooker must be installed in a workmanlike manner in accordance with the instructions in
this manual and locally applicable regulations. This manual will be handed over to the user after
installation.
Before connection, check :
 That the electrical supply of the system is compatible with the voltage and power of the range.
 The user's fixed installation must include an all-pole circuit-breaker of approved type.
CAUTION :
Connection :
- Cable insulation must be type 245 IEC 57 or 245 IEC 66
- The length of the conductors of the power cable between the strain relief device and the terminals
must be such that the conductors become taut before the earth conductor in case of traction on
the cable.
- If this unit is permanently connected to a fixed electrical cable, the cable should be equipped with
a fault leak protector.
- If this unit is connected to a wall outlet, the outlet should be permanently accessible.
- Remove cover ( or covers) (see
- Use a standard flexible cable to connect to terminal block (see
- Secure the cable by means of cable clamp (see
It is hazardous to put the appliance into service without connecting it to suitable ground.
No liability can be accepted for accidents resulting from non-compliance with this
requirement or incorrect grounding.
B
C
D
INSTALLER'S MANUAL

ELECTRIC CONNECTION

A
1
/ figure
), to the back of the unit identified by
C
A
The supply of three phase 400 without neutral is not possible
1
Sully - Ft 124a - GB - Rév 06 - Modifié le : 07/10/2013
B
/ figures
1
/ figure
).
1
2
3
4
5
L
N
230 V 1N ~ 50 Hz
1
2
3
4
5
L1
L2 L3
N
400 V 3N ~ 50 Hz
.
1
2
&
).
1
2
3
4
5
L1
L2
L3
230 V 3 ~ 50 Hz
1
2
L
N
230 V 1N ~ 50 Hz
2
17/42