All work on or repair of an appliance must be carried out by a qualified engineer.
Greasing gas valve (Hobs and Ovens)
The valve may lose its grease through use. It is therefore necessary to grease the valve in order to
make it leaktight and facilitate turning.
1 - Shut off the valve and / or the main electrical supply of the unit.
2 - Take out the knob corresponding to the gas valve to be greased.
3 - Unscrew the head from the body of the burner valve.
4 - Grease the tap shaft (high temperature lubricant, for example : SILICAL GEL ™ BARBAHL).
Caution ! Any excess grease should be removed.
Reverse operation 3 to 1 (in that order) to put valve and knob back on.
Electric Limiting thermostat :
In accordance with the construction regulations, the limiting thermostat is intended to protect the
range from overheating.
In the event of overheating the limiting thermostat is triggered and cuts out the range's oven
functions.
The advanced technology used in the limiting means that it is very sensitive to impacts and
vibration that may occur during transport and handling.
The limiter may therefore be unexpectedly triggered when the oven is first heated and stop the
oven from working.
To reset limiting thermostat for electric ovens with :
Gas hob :
Remove the ventilation strip from the rear of the hob
1-
Unscrew the cover protecting the knob
2-
Press the knob marked (see
3-
Electric hobs :
The button is behind the ventilation strip .
To have access there, it is necessary to use a small screwdriver to press on the push-button and
reset limiting thermostat (see