Download Print this page

Installing / Positioning; Electrical Connection - Lacanche LAE 020 I User Manual

Advertisement

INSTALLING / POSITIONING

CAUTION:
• The buyer agrees to install the appliance in accordance with recognised best practices and the
regulations in force.
• Any technical operation such as installation, repair or adjustment of the appliance must be carried
out by a qualified technician.
• Do not lift the appliance by the front rail. Damages caused in this way are not covered by the
warranty.
DELIVERY AND UNPACKING:
The appliance is delivered on a wooden pallet, packed with cardboard.
• Unpack and check the appliance for damage upon receipt. In case of damage, mark the
delivery note accordingly, and within 48 hours notify the carrier in writing by registered mail with
acknowledgement of receipt.
INSTALLER'S MANUAL

ELECTRICAL CONNECTION

The installation must be carried out in accordance with recognised best practices, the instructions given
in this manual and the regulations in force in the country of installation.
The means for disconnection must be provided in fixed installations in accordance with all relevant
regulations.
BEFORE CONNECTION:
Check that:
 The mains supply is compatible with the voltage and power of the appliance.
 The user's fixed installation features an approved main isolating device acting on all phases.
CONNECTION:
- Use a standard flexible cable (245 IEC 57 or 245 IEC 66, or any other cable with the same
characteristics).
- The power supply cables between the isolating traction device and the terminals must be of such
lengths as to ensure in the event of traction that the live cables become taut before the earth cable.
- If the appliance is permanently connected to a fixed electrical installation, this installation must be
fitted with a suitable leakage current protection device.
- If the appliance is connected with a cable fitted with a plug, the socket must be accessible at all times.
A
- Remove the cover(s)
from the back of the appliance identified by the label
- Connect a standard cable suitable for the voltage to the terminals. (Ensure that the jumper
B
connectors are correctly fitted)
- Secure the cable with the cable clampe
- Pass the lead through the grommet
B
C
D
We cannot be held responsible for accidents due to missing or incorrect earth connection.
20
.
C
.
D
.
1
2
3
4
5
L
N
220-240 V 1N ~ 50 Hz
A
1
2
3
4
5
L1
L2 L3
N
400 V 3N ~ 50 Hz
L'alimentation en tri 400 sans neutre n'est pas possible.
It is dangerous to operate the appliance
without having it properly earthed.
1
INSTALLER'S MANUAL
.
1
2
3
4
5
L1
L2
L3
230 V 3 ~ 50 Hz
1
2
L
N
220-240 V 1N ~ 50 Hz

Advertisement

loading