Scanner Settings
Scaling: .............................................
Highlight/Shadow: ...........................
Brightness: .......................................
Gamma Curve: .................................
Data Output
Color Mode: ......................................
Grayscale Mode: ..............................
Interface: ..................................................
Power Requirements
Voltage: .............................................
Power Consumption: ..............................
Environmental Ranges
Operating Temperature: ..................
Relative Humidity: ...........................
Dimensions: .............................................
Net Weight: ...............................................
Systems Supported:
*Product Specifications subject to change without notice.
2
1% to 200% in 1% increments at 600 dpi Resolution
255 steps
-100% ~ 100%
Downloadable Curves
30 Bits (Hardware) 36 Bits (System)
10 Bits (Hardware) 12 Bits (System)
USB
DC12 V (AC)
Maximum 12 Watts
10° C ~ 35° C
10% ~ 85%
471mm x 312mm x 98mm
3.65 Kg
PC