PROVISION FOR VENTILATION
The appliance should be installed into a room or space with an air supply in
accordance with BS 5440-2: 2000.
For rooms with a volume of less than 5 m
area will be required.
For rooms with a volume of between 5 m
2
50 cm
free area will be required unless the room has a door which opens directly
to the outside air in which case no permanent ventilation is required.
For rooms with a volume greater than 10 m
NB. Regardless of room size, all rooms containing the appliance must have direct
access to the outside air via an openable window or equivalent.
Where there are other fuel burning appliances in the same room, BS 5440-2: 2000
should be consulted to determine the correct amount of free area ventilation
requirements.
The above requirements allow also for use of a gas oven and grill but if there are
other gas burning appliances in the same room, consult a qualified engineer.
28
3
- permanent ventilation of 100 cm
3
3
and 10 m
a permanent ventilation of
3
- no permanent ventilation is required.
2
free