Possible types of benefit kWh rate power supply
Possible connections and requirements to connect the equipment to
such power supply are illustrated in the figures below:
[D-01]=1
1
L N
1
2
S2S
3
2
L N
1
2
S2S
3
3
L N
1
S2S
2
3
3
17 18
X40A
1
Benefit kWh rate power supply box
2
Receiver controlling the signal of the electricity company
3
Power supply to outdoor unit
4
Voltage free contact
0
Allowed
X
Not allowed
CAUTION
In case of benefit kWh rate power supply installation,
remove the wiring bridges on X2M before installing the
normal kWh rate power supply.
When the outdoor unit is connected to a benefit kWh rate power
supply, the voltage free contact of the receiver controlling the benefit
kWh rate signal of the electricity company must be connected to
clamps 17 and 18 of X2M (as illustrated in the figure above).
When parameter [D-01]=1 at the moment that the benefit kWh rate
signal is sent by the electricity company, that contact will open and
the unit will go in forced off mode
When parameter [D-01]=2 at the moment that the benefit kWh rate
signal is sent by the electricity company, that contact will close and
the unit will go in forced off mode
type 1
The benefit kWh rate power supply is of the type that power supply is
not interrupted.
type 2 and 3
The benefit kWh rate power supply is of the type that power supply
will be interrupted after elapse of time or is interrupted immediately.
(1) When the signal is released again, the voltage free contact will close and
the unit will restart operation. It is therefore important to leave the auto
restart function enabled. Refer to "[3] Auto restart" on page 32.
(2) When the signal is released again, the voltage free contact will open and
the unit will restart operation. It is therefore important to leave the auto
restart function enabled. Refer to "[3] Auto restart" on page 32.
EBHQ006+008BAV3 + EKCBX/H008BAV3
Unit for air to water heat pump system
4PW64602-1A – 09.2010
[D-01]=2
1
L N
1
2
S2S
4
3
2
L N
1
2
S2S
4
3
3
L N
1
S2S
2
3
4
X2M
A1P
(1)
.
(2)
.
CAUTION
Benefit kWh rate power supplies that completely shut
power supply like illustrated above as types 2 and 3
are not allowed for this application because of the
water freeze prevention that would not be powered.
When connecting the equipment to a benefit kWh rate
power supply, change field settings [D-01] and both
[D-01] and [D-00] in case the benefit kWh rate power
supply is of the type that power supply is not
interrupted (like illustrated above as type 1). Refer to
"[D] Benefit kWh rate power supply/Local shift value
4
weather dependent" on page 38 of chapter "Field
settings".
NOTICE
If the benefit kWh rate power supply is of the type that
power supply is not interrupted, the unit will be forced to
off. Controlling the solar pump is still possible.
4
12.7. Indoor unit – Internal wiring – Parts table
Refer to the wiring diagram sticker on the top plate of the indoor unit.
The abbreviations used are listed below:
A1P .......................... Main PCB
A2P .......................... User interface PCB
A3P (EKRTW/R) ...... Thermostat (PC = power circuit)
A3P (EKSR3PA)....... Solar pumpstation PCB
A4P (EKRPB1HB).... Digital input/output PCB
A4P (EKRTR)........... Receiver PCB
BSK (EKSR3PA) ...... Solar pumpstation relay
E4H .......................... Booster heater
F2B .......................... Fuse booster heater
FU1 .......................... Fuse (T, 3.15 A, 250 V) for PCB
FU2 .......................... Fuse (T, 5 A, 250 V)
Fus,FuR ................... Fuse (5 A, 250 V) for digital input/output PCB
K3M.......................... Booster heater contactor
M2S.......................... 2-way valve for cooling mode
M3S.......................... 3-way valve floor heating/domestic hot water
PHC1 ....................... Optocoupler input circuit
Q1DI......................... Earth leakage circuit breaker
Q2L .......................... Thermostat protector booster heater
R1H (EKRTR) .......... Humidity sensor
R1T (EKRTW) .......... Ambient sensor
R2T (EKRTETS) ...... External sensor (floor or ambient)
R5T .......................... Domestic hot water thermistor
S2S .......................... Benefit kWh rate power supply contact
S3S .......................... Dual setpoint 2 contact
S4S .......................... Dual setpoint 1 contact
SS1 .......................... DIP switch
TR1 .......................... Transformer 24 V for PCB
V1S,V2S .................. Spark surpression 1, 2
X1M~X15M .............. Terminal strips
X3Y,X6Y,X13Y.......... Connector
................. Field wiring
.................... Terminal strip
.................... Connector
........................... Terminal
............................ Protective earth
BLK .......................... Black
BLU .......................... Blue
BRN ......................... Brown
GRN ......................... Green
GRY ......................... Grey
ORG......................... Orange
Installation manual