Outdoor Unit / RK(X)H-C, ARK(X)H-C, R(Y)N-C
Step
3
Remove the terminal
cover gasket.
2. Remove the compressor.
1
Remove the nut of the
compressor.
Before starting the work,
make sure that the
refrigerant gas has been
completely removed out of
the refrigerant circulating
system.
2
Heat the soldered
portion of the discharge
side, and disconnect
the discharge pipe.
210
Procedure
Points
Take a note.
W
V
U
U : Red
V : Yellow
W: Blue
Gasket
(R4507)
Warning
If the refrigerant gas leaks
during work, ventilate the
room. (In case the refrigerant
gas is exposed to fire, it will
cause toxic gas.)
Apply welding-work sheet or
iron plate so that the flame
of gas welding machine
should not affect the nearby
parts.
Be careful not to burn the
compressor terminal and the
nameplate.
Be careful not to burn the
heat exchanger fin.
Warning
The refrigerator oil of the
compressor may catch fire.
Provide wet cloth for prompt
extinction in emergency.
Caution
From the point of view of
environmental protection, do
not release the refrigerant
gas to the atmosphere, but
always collect it with use of a
collecting device.