LSI Ultra320 SCSI User Manual

LSI Ultra320 SCSI User Manual

Lsi logic host adapters user's guide ultra320 scsi
Hide thumbs Also See for Ultra320 SCSI:
Table of Contents

Advertisement

Quick Links

USER'S
GUIDE
Ultra320 SCSI
Host Adapters
A p r i l 2 0 0 4
Version 2.2
®
DB15-000192-03

Advertisement

Table of Contents
loading

Summary of Contents for LSI Ultra320 SCSI

  • Page 1 USER’S GUIDE Ultra320 SCSI Host Adapters A p r i l 2 0 0 4 Version 2.2 ® DB15-000192-03...
  • Page 2: Electromagnetic Compatibility Notices

    Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product. LSI Logic is not responsible for any radio or television interference caused by unauthorized modification of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by LSI Logic.
  • Page 3 LSI Logic; nor does the purchase or use of a product from LSI Logic convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI Logic or third parties.
  • Page 4 Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved.
  • Page 5 Preface This document is the user’s guide for all LSI Logic Ultra320 SCSI Host Adapters. It contains a functional description of the Ultra320 SCSI host adapters as well as physical and electrical specifications. It also contains instructions for installing the host adapters and for connecting SCSI devices to them.
  • Page 6 Related Publications LSI53C1020/1020A PCI to Ultra320 SCSI Controller Technical Manual, Document No. DB14-000176-06 LSI53C1030 PCI to Dual Channel Ultra320 SCSI Multifunction Controller Technical Manual, Document No. DB14-000156-05 Fusion-MPT™ Device Management User’s Guide, Document No. DB15-000186-01 Integrated RAID User’s Guide, Document No. DB15-000292-00...
  • Page 7: Table Of Contents

    Connecting External SCSI Devices Integrated Mirroring (IM) Solution Integrated Striping (IS) Solution LSI20320 Single Channel Host Adapters LSIU320 and LSI20320A Single Channel Host Adapters Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. 2-10 2-12 2-13 2-14 2-15 2-15...
  • Page 8 Version 2.2 LSI21320 Dual Channel Host Adapters LSI22320 Dual Channel Host Adapters LSI22320E Dual Channel Host Adapters Electrical Characteristics Thermal and Atmospheric Characteristics Safety Characteristics Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. 3-10 3-12 3-12 3-12 3-13 3-13...
  • Page 9 SCSI ID Record for Dual Channel Host Adapter Host Adapter Installation Checklist Ultra320 SCSI to PCI/PCI-X or PCI Express x4 Host Adapters Host Adapter Characteristics Maximum Power Requirements Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. 2-10 2-11 3-11 2-13 2-14 3-12...
  • Page 10 Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved.
  • Page 11: Chapter 1 Quick Installation Procedures

    1.1 General Description LSI Logic provides high-performance, cost-effective Ultra320 SCSI controllers and host adapters. and their associated host adapters that support Ultra320 SCSI. For specific information about the Ultra320 SCSI controllers, refer to the Related Publications of an adapter name indicates a feature such as: A = low cost;...
  • Page 12: Quick Host Adapter Installation

    (SE) devices and LVD devices, the entire bus drops to the lower SE speed, limiting bus performance to Ultra SCSI. The Ultra320 SCSI host adapters support all major operating systems (OS), such as Windows (NT 4.0, 2000, 2003, and XP), Linux, NetWare, UnixWare, SCO OpenServer 5.x, and Solaris SPARC.
  • Page 13 Step 13. Plug in all power cords and turn on power to all devices and your computer. Step 14. Wait for your computer to start up. The host adapter installation is complete. Quick Host Adapter Installation Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved.
  • Page 14: Quick Windows Driver Installation

    Service Packs 5 or higher after Windows NT 4.0 has been installed. Refer to the Fusion-MPT™ Device Management User’s Guide for detailed configuration and installation instructions for all firmware and drivers. Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved.
  • Page 15: Chapter 2 Detailed Host Adapter Installation

    Chapter 2 Detailed Host Adapter Installation This chapter provides detailed instructions on how to install the LSI Logic Ultra320 SCSI host adapters and includes these topics: Section 2.1, “Installing Your Ultra320 SCSI Host Adapter” Section 2.2, “SCSI Device Cables” Section 2.3, “Connecting SCSI Devices”...
  • Page 16: Installing Your Ultra320 Scsi Host Adapter

    Step 2. Open your computer cabinet by removing its cover. Step 3. Be sure to touch a grounded metal surface to discharge static Caution: Step 4. Remove your Ultra320 SCSI host adapter from its packaging Figure 2.1 illustrates the LSI22320E-R host adapter.
  • Page 17: Inserting The Host Adapter

    Step 5. Find an unused PCI/PCI-X/PCI Express slot. Note: 2.1.2 Inserting the Host Adapter Follow these steps to install your Ultra320 SCSI host adapter in the PC mainboard. Step 1. Remove the blank bracket panel on the back of the computer that Step 2.
  • Page 18: Inserting The Host Adapter

    The bracket should fit into the empty space where the blank bracket panel was removed. before you connect the internal and external SCSI devices. Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. PCI Connectors PCI Express...
  • Page 19: Scsi Device Cables

    2.2 SCSI Device Cables For reliable Ultra320 operation, be sure to use an Ultra320-rated SCSI device cable. The internal Ultra320 SCSI device cable also has built-in low voltage differential (LVD) and single-ended termination. This built-in feature is included because most LVD SCSI hard disk drives are not made with on-board low voltage differential termination.
  • Page 20: Scsi Cable - 68-Pin Vhdci To 68-Pin Vhdci

    Detailed Host Adapter Installation Version 2.2 SCSI Cable – 68-Pin VHDCI to 68-Pin VHDCI SCSI Cable – 68-Pin VHDCI to 68-Pin HD SCSI Cable – 68-Pin HD to 68-Pin HD Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved.
  • Page 21: Connecting Scsi Devices

    Figure 2.8 Connecting SCSI Devices Version 2.2 cable into the internal connector on the host adapter, as Figure 2.8 shows. Connecting Internal SCSI Cable to Host Adapter Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. for examples of...
  • Page 22: Connecting Multiple Internal Scsi Devices

    SCSI host adapter. Refer to Section 2.4, “Terminating the SCSI Bus,” on page 2-12 details on SCSI bus termination. Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. Figure 2.9 shows. You can connect...
  • Page 23: Connecting The Led Cable

    J5. Connecting SCSI Devices Version 2.2 shows. Connector J5 is not keyed. Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. Cable LED Connector J5 Left two pins are for Channel A...
  • Page 24: Connecting External Scsi Devices

    SCSI cable into the SCSI connector on the first external SCSI device. Figure 2.11 shows how to connect a single external SCSI device. If you have the correct cable, it matches the external connector. Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved.
  • Page 25: Connecting Multiple External Scsi Devices

    Figure 2.12 “Terminating the SCSI Bus,” on page 2-12 bus termination. Connecting SCSI Devices Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. Disable termination on all devices not at the end of the bus. Host Adapter...
  • Page 26: Terminating The Scsi Bus

    SCSI bus. Termination for host adapters with only one connector per channel is always enabled for the channel. 2-12 Detailed Host Adapter Installation Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved.
  • Page 27: Setting Scsi Ids

    Typically, you set the SCSI ID of the SCSI device with jumpers or with a switch on the device. You must not duplicate SCSI IDs on a SCSI bus. LSI Logic recommends that you record the SCSI IDs of all SCSI devices. Table 2.1 Table 2.1...
  • Page 28: Completing The Installation

    Version 2.2 Table 2.2 Host Adapter Installation Checklist your computer. To change default configurations of the Ultra320 SCSI host adapters, refer to the Fusion-MPT™ Device Management System User’s Guide. Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. Done...
  • Page 29: Setting Up Integrated Raid (Ir) Solution

    Integrated Striping™ (IS) solution, which provides features of RAID 0 By simplifying the IM and IS options and by providing firmware support in its host adapters, LSI Logic can offer the Integrated RAID solution at a lower cost than a dedicated processor based RAID implementation.
  • Page 30: Integrated Striping (Is) Solution

    To set up the Integrated RAID (IM and IS) features, refer to the Integrated RAID User’s Guide. 2-16 Detailed Host Adapter Installation Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved.
  • Page 31: Chapter 3 Ultra320 Scsi Host Adapter Characteristics

    Chapter 3 Ultra320 SCSI Host Adapter Characteristics This chapter describes the LSI Logic Ultra320 SCSI host adapters. This chapter includes these topics: Section 3.1, “Ultra320 SCSI Host Adapters” Section 3.2, “Host Adapter Characteristics” Section 3.3, “Technical Specifications” 3.1 Ultra320 SCSI Host Adapters...
  • Page 32: Lsi20320 Single Channel Host Adapters

    Dual Channel LSI22320E-R Dual Channel The component height on the top and bottom of the Ultra320 SCSI host adapters follows the PCI Local Bus Specification, Revision 2.2, PCI-X Addendum to the PCI Local Bus Specification, Revision 1.0a, and PCI Express to PCI/PCI-X Bridge Specification, Revision 1.0. The Ultra320 SCSI host adapters are used in PCI/PCI-X and PCI Express computer systems with PCI standard and PCI low profile bracket types.
  • Page 33: Lsi20320, Lsi20320-R, And Lsi21320L-R Host Adapter Drawing

    Drawing Channel A Internal SCSI Connector Channel A Ultra320 SCSI LVD/SE Ultra320 SCSI Host Adapters Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. Subsystem Vendor ID 0x1000 0x1000 0x1000 HDR2 Connector for LSI53C1020 J5 – PCI and PCI-X 64-Bit Edge Connector...
  • Page 34: Lsiu320 And Lsi20320A Single Channel Host Adapters

    3.1.2 LSIU320 and LSI20320A Single Channel Host Adapters The LSIU320 and LSI20320A series of host adapters are single channel Ultra320 SCSI host adapters that provide one Ultra320 SCSI channel. The SCSI Channel A interface for is made through connectors J2 and J3.
  • Page 35: Lsiu320, Lsiu320-R, Lsi20320A, And Lsi20320A-R Host Adapter Drawing

    LSIU320, LSIU320-R, LSI20320A, and LSI20320A-R Host Adapter Drawing Channel A Ultra320 SCSI LVD/SE Channel A Ultra320 SCSI LVD/SE Ultra320 SCSI Host Adapters Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. J4 LED Connector LSI53C1020A J1 – PCI and PCI-X...
  • Page 36: Lsi21320 Dual Channel Host Adapters

    3.1.3 LSI21320 Dual Channel Host Adapters The LSI21320 series of host adapters are dual channel Ultra320 SCSI host adapters that provide two Ultra320 SCSI channels. The SCSI Channel A interface is made through connectors J2 and J4. The SCSI Channel B interface is made through connector J3.
  • Page 37 LSI21320 and LSI21320-R Host Adapter Drawing Channel A Ultra320 SCSI LVD/SE Channel A Ultra320 SCSI LVD/SE Ultra320 SCSI Host Adapters Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. J6 for Channels A and B Channel B Ultra320 SCSI LVD/SE LSI53C1030...
  • Page 38: Lsi22320 Dual Channel Host Adapters

    3.1.4 LSI22320 Dual Channel Host Adapters The LSI22320 series of host adapters are dual channel Ultra320 SCSI host adapters that provide two Ultra320 SCSI channels. The SCSI Channel A interface is made through connectors J2 and J6. The SCSI Channel B interface is made through connectors J3 and J4. See Figure 3.4...
  • Page 39 Channel B Ultra320 SCSI LVD/SE Channel A Ultra320 SCSI LVD/SE Ultra320 SCSI Host Adapters Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. Channel A Ultra320 SCSI LVD/SE LSI53C1030 J1 – PCI and PCI-X Channel A Ultra320 SCSI LVD/SE LSI53C1030T J1 –...
  • Page 40: Lsi22320E Dual Channel Host Adapters

    3.1.5 LSI22320E Dual Channel Host Adapters The LSI22320E series of host adapters are dual channel Ultra320 SCSI host adapters that provide two Ultra320 SCSI channels. The SCSI Channel A interface is made through connector J2. The SCSI Channel B interface is made through connectors J3 and J5. See...
  • Page 41 Channel B Ultra320 SCSI LVD/SE Channel B Ultra320 SCSI LVD/SE LSI53C1020A Channel A Ultra320 SCSI LVD/SE J1 – PCI-Express Ultra320 SCSI Host Adapters Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved. HDR2 LSI53C1020A PCI Express Bridge 3-11...
  • Page 42: Host Adapter Characteristics

    3.3 Technical Specifications The design and implementation of the Ultra320 SCSI host adapters minimize electromagnetic emissions, susceptibility to radio frequency energy, and the effects of electrostatic discharge. The adapter carries the CE mark, C-Tick mark, FCC Self-Certification logo, Canadian...
  • Page 43: Thermal And Atmospheric Characteristics

    5% to 90% noncondensing 3.3.3 Safety Characteristics All Ultra320 SCSI host adapters meet or exceed the requirements of UL flammability rating 94 V0. Each bare board is also marked with the supplier’s name or trademark, type, and UL flammability rating. Because these boards are installed in a PCI bus slot, all voltages are below the SELV 42.4 V limit.
  • Page 44 3-14 Ultra320 SCSI Host Adapter Characteristics Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved.
  • Page 45: Appendix A Glossary Of Terms

    The electrical connection required at each end of the SCSI bus, Termination composed of active voltage regulation and a set of termination resistors. Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, and Ultra320 SCSI require active termination. BIOS Basic Input/Output System. Software that provides basic read/write capability.
  • Page 46 RAID controller. Integrated The LSI Logic Integrated Striping (IS) solution provides features of RAID Striping (IS) 0. The IS feature is a low-cost solution with many of the features of a more expensive RAID striping solution.
  • Page 47 SCSI signal to a common ground. In contrast, differential SCSI uses a separate ground for each signal. SureLINK The domain validation method developed and used by LSI Logic. SureLINK Domain Validation provides three levels of integrity checking: Basic (level 1), Enhanced (level 2), and Margined (level 3).
  • Page 48 A standard for SCSI data transfers. It allows a transfer rate of up to 320 Mbytes/s over a 16-bit SCSI bus. VHDCI Very High Density Cable Interconnect. VHDCI cables connect external SCSI devices to the host adapter. Glossary of Terms Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved.
  • Page 49: Customer Feedback

    Thank you for your help in improving the quality of our documents. Ultra320 SCSI Host Adapters User’s Guide Version 2.2 Copyright © 2002–2004 by LSI Logic Corporation. All rights reserved.
  • Page 50 Reader’s Comments Fax your comments to: Please tell us how you rate this document: Ultra320 SCSI Host Adapters User’s Guide. Place a check mark in the appropriate blank for each category. Completeness of information Clarity of information Ease of finding information...
  • Page 51 You can find a current list of our U.S. distributors, international distributors, and sales offices and design resource centers on our web site at http://www.lsilogic.com/contacts/index.html...

Table of Contents