Configuring Power

After connecting the access point to a power source, its status LED might be
amber, which can indicate that the access point is unable to verify that the
PSE is supplying sufficient power. In such cases, you need to configure
settings on the access point or the switch to identify your power source.
Identify your power source and switch condition, and then make sure that
your devices are configured as shown in the table on page 19.
Follow these steps to configure the system power settings using the GUI:
1. Open your browser and enter the access point IP address in the address
field. A login and password screen appears.
2. Enter the username Cisco and password Cisco. The username and
password are case sensitive.
3. When the access point does not receive enough power for full operations,
it is in low power mode. If your access point is in low power mode, a
warning message appears indicating that all radios are disabled due to
insufficient power. Click OK to continue. The System Configuration
page appears.
4. Scroll down to the System Power Settings section as shown in the
following illustration.