Error pattern
9562/9563
9880
Check the time and
set the clock
F161
Less than minimum
required flow rate
F164
Less than minimum
hot water dispensing
flow rate
User Manual WMF espresso
Messages and instructions | Troubleshooting
Action instructions
Empty the portafilter
Check whether the correct sieve is loaded in the
portafilter
Make sure that the portafilter is emptied each time
a beverage is prepared
Clean the ground coffee chute
Clean the brewing group manually
w Care w Clean the brewing group manually, page 52
In the recipe for the beverage that was last dispensed,
increase the ground coffee quantity by 0.1 grams.
if error not remedied
Switch off the coffee machine
Call WMF Service
Check the time and set the clock
Switch off the coffee machine and on again
if error not remedied
Call WMF Service
Clean the portafilter and the brewing sieve
Switch off the coffee machine
Remove the hot water spout and clean the screen
Caution. Hot liquids
Switch on the coffee machine
67