2. INSTALLATION PROCEDURE
2.2

CONNECTING THE DRAWER

1. The solenoid included in the drawer to be connected should have the minimum of 36 ohm
resistance. Under-specified solenoid may cause a machine failure.
2. The output current of the drawer should not exceed 0.8A, as there is a risk of a machine failure.
3. The drawer interface connector is exclusively for connecting a drawer. Do not connect a phone
line or any other cables than the specified drawer cable. Doing so may cause a failure of the
phone line and the printer.
Connectable drawers must meet the following conditions.
• The drawer which includes the Drawer Drive Circuit (DC 24V specification).
• The drawer which has 6-pin modular connector.
1.
Turn the printer power OFF.
2.
Connect the drawer cable to the drawer interface connector in the correct orientation.
WARNING!
Pin
Signal
1
FG
2
DRAWER1
3
DRSW
4
VDR
5
DRAWER2
6
GND