5 INSTALLATION
Connection instruction
The power source is connected to 460V from the factory. If a different mains voltage is
required, the cable on the printed circuit board must be moved and placed on the correct pin.
See picture above. This operation must be carried out by personnel with the appropriate
electrical knowledge.
Installation of mains cable
A mains cable needs to be installed. It is then important that the ground connection to the
bottom plate be made in a correct way. See the picture above, for the order in which the
washers, nuts and screws are placed.
0463 341 131
- 13 -
© ESAB AB 2013